- 6 -
Note:
Drain pan and drain hose must be installed before using reverse cycle models.
Drain hose or tubing can be purchased locally to satisfy your particular needs.
Drain water for another style
:
To get the maximum cooling efficiency, the air conditioner is designed to splash the condensation water on the
condenser coil.
To the cooling only unit,
If the splashing sound annoys you, you can provide an outside drain by using the follo
-wing procedure, which
may however cause a small loss of performance.
1. Slide out the chassis from the cabinet.
2. Remove the rubber plug from the body base plate.
3. Install the drain pan to the corner of the cabinet with 2 screws.
4. Connect the drain hose to the outlet on the drain pan bottom.
5. Slide the chassis into its original place in the cabinet.
Drain water for one style:
To get the maximum cooling efficiency,
the air conditioner is designed to splash the condensate on the
condenser coil.
If the splashing sound annoys you, you can provide an outside drain by using the following procedure,
which may however cause a small loss of performance.
1.
There is a drainage outlet at the back of the unit.
2.
Remove cover from the drainage outlet, and then connect drainage joint to it with screw.
3.
Connect the drain hose to the outlet.
Note:
Drain hose or tubing can be purchased locally
to satisfy your particular needs.
Drainage outlet
Washer
Drainage joint
Install
Cover
Remove