background image

4

© Copyright, GREE Canada, 2021

       CAUTION!

 

 

Ventilate the room well when 

used together with a stove, etc.

Do not clean the air conditioner

with water.

It may cause an injury.

Water may enter the unit and degrade

the insulation. It may cause an 

electric shock.

An oxygen shortage may occur.

When the air filter is to be

removed, do not touch the metal

parts oft he unit.

Do not use for special purposes.

Do not clean unit when power is on

as it may cause fire and electric

shock, it may cause an injury.

This could injure the pet or plant.

Do not use this air conditioner to

preserve precision devices, food,

pets, plants, and art objects. It may

cause deterioration of quality, etc.

When the unit is to be cleaned,

switch off, and turn off the

circuit breaker.

Do not put a pet or house plant

where it will be exposed to direct

air flow.

Turn off the main power switch

when not using the unit for

a long time.

Hold the plug by the head of the

power plug when taking it out.

Operation with windows opened may

cause wetting of indoor and soaking

of household furniture.

It may cause failure of product or fire.

Stop operation and close the

window in storm or hurricane.

Always insert the filters securely.

Clean the filter once every

two weeks.

Ensure that the installation 

bracket of the outdoor appliance 

is not damages due to prolonged 

exposure.

It may cause failure of appliance or

accident.

Operation without filters may cause

failure.

Do not place obstacles around

air-inlets or inside of air-outlet.

Do not drink water drained from

air conditioner.

Do not place heavy object on the

power cord and ensure that the

power cord is not compressed.

Appearance may be deteriorated 

due to change of product color or

scratching of its surface.

It contains contaminants and could

make you sick.

Do not use strong detergent 

such as wax or thinner but use 

a soft cloth .

Use caution when unpacking and installing.

Sharp edges could cause injury.

If water enters the unit, turn the unit off at the power

outlet and switch off the circuit breaker. Isolate supply

by taking the power plug out and contact a

qualified service technician.

It may cause electric shock and

damage.

If bracket is damaged, there is 

concern of damage due to falling 

of unit.

There is danger of fire or electric 

shock.

Power supply cord with 3-prong grounding plug and current detection device.

Do not, under any circumstances, cut, 

remove or bypass the grounding prong.

SAFETY PRECAUTIONS

Summary of Contents for GJC10BL-A6NRNE2D

Page 1: ...il Quebec Canada Made in China OWNER S MANUAL WINDOW TYPE AIR CONDITIONER MODELS GJC10BL A6NRNE2D GJC12BR A6NRNE2B Thank you for choosing our product Please read this owner s manual carefully before o...

Page 2: ...ve you a great deal of time and money over the life of your air conditioner You ll find many answers to common problems in the chart of troubleshooting tips If you review our chart of Troubleshooting...

Page 3: ...amage your health Do not modify power cord length or share the outlet with other appliances Do not operate with wet hands or in damp environment Always install circuit breaker and a dedicated power ci...

Page 4: ...se the window in storm or hurricane Always insert the filters securely Clean the filter once every two weeks Ensure that the installation bracket of the outdoor appliance is not damages due to prolong...

Page 5: ...is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle 4 Ensure the receptacle is accessible after the unit installa...

Page 6: ...s or objects into air inlet or air outlet It may cause personal injury or damage 10 Do not step on air conditioner or put heavy objects It may cause damage or personal injury 11 Do disconnect power su...

Page 7: ...outdoor temperature for cooling only unit is 18 C 43 C 64 4 109 4 F for heat pump unit is 7 C 43 C 19 4 109 4 F WORKING TEMPERATURE RANGE Indoor side DB WB C F Outdoor side DB WB C F Maximum cooling 3...

Page 8: ...u operate the air conditioner through remote controller or control panel 2 3 6 7 1 Power button 2 Mode button 3 Fan Speed button 4 Timer button Filter check button 5 Boutton 6 Display 7 1 4 5 Light in...

Page 9: ...n Press Fan Speed button can adjust the fan speed FAN ONLY Under this mode air conditioner will not cool or heat only blow wind Fan indicator will be on Press Fan Speed button can adjust the fan speed...

Page 10: ...each pressing of or button temperature will increase or decrease 1 F Temperature setting range 61 86 F Under timer setting status after each pressing of or button time will increase or decrease 0 5h o...

Page 11: ...ff the unit and then turn it on with remote controller or switch to energy saving mode after turning on the unit with remote controller MODE button Each time you press the button a mode is selected in...

Page 12: ...m press this button twice Under switch on or switch off state you may hold and buttons simultaneously for 3 seconds to set the lamp on or off and send the code After being energizedthe lamp is default...

Page 13: ...ing rod to select left right air outlet direction according to your requirement You can adjust the air outlet frame to select up down air outlet direction according to your requirement Instruction for...

Page 14: ...tightly NOTICE Clean the filter about once every three month If there are lots of dust in operation environment you can increase the clean times Due to there s shaft metal fins in the air conditioner...

Page 15: ...unit Please contact after sales maintenance person Poor cooling heating Is the power too low Wait after voltage is resumed Whether the air filter is too dirty Clean the air filter Whether the set tem...

Page 16: ...e s abnormal sound during operation Whether the unit is interfered by thunder radio etc Disconnect power put through the power again and then turn on the unit again You can heard water flowing sound W...

Page 17: ...nditioner and disconnect the power immediately After that please contact dealer at once Power cord is overheating or damaged There s abnormal sound during operation There s burning smell Power cord te...

Page 18: ...e medical equipment 3 The place near coast area 4 The place with oil or fumes in the air 5 The place with sulfureted gas 6 Other places with special circumstances Requirement of complete unit 1 There...

Page 19: ...wrong wiring may lead to electric shock fire hazard or malfunction 5 Properly connect the live wire neutral wire and grounding wire of power socket 6 Do not put through the power before finishing ins...

Page 20: ...llation Air conditioner Sealing strip with adhesive 2 Sealing strip without adhesive Accordion panel seal 2 Foam Insulation 2 Screw A 4 Screw B 6 User Manual Frame locking bracket 1 Window locking bra...

Page 21: ...d is available STANDARD WINDOW WEATHER PROOF TYPE WINDOW The height of window frame is higher than windowsill for some weather proof type window which will affect the installation of air conditioner I...

Page 22: ...1 Stick one accordion panel seal respectively on the left side and right side of accordion panel installation frame as shown in the figure Installation procedure Top mounting rail Top mounting rail s...

Page 23: ...guide rail should be stick at the windowsill Top mounting rail stays at the middle lower side of window and then window can stick to the top mounting rail when closing it Please note that the air cond...

Page 24: ...6 Plug foam top window gasket 1 Cut the foam top window gasket into the length same to the width of window Plug the foam between glasses and window to prevent rain and insects getting into the room P...

Page 25: ...ioner and window frame Sponge Sticking Method and Procedures L L 2 Take out foam insulation from the package Cut off the foam insulation in rectangular shape with scissors 3 Stick foam insulation even...

Page 26: ...ring the warranty period if this Air Conditioner fails under normal use GREE will at its option either repair the unit or replace it free of charge within a reasonable period of time after the Air Con...

Reviews: