background image

3

Fan Speed button

Press this button can select your required fan speed in turn. Corresponding speed indicator will be on.

Low

Med

High

Auto

When there’s malfunction, dual-8 nixie tube will display corresponding malfunction code.

E8 It can be eliminated after power off and re-up electricity. 

If not, please contact qualified professionals for service.

EP malfunction of indoor ambient temperature sensor or

indoor evaporator temperature sensor

12

4

Sleep button

Press this button to go into the SLEEP operation mode. Press any button to cancel this function. This function can be 

started up under fan mode and cooling mode. Under cooling mode, the unit operates at low fan speed and it 

automatically adjusts the temperature; under fan mode, the unit operate at low fan speed.

5

Delay 1-24hr button

Press this button can set TIMER ON and TIMER OFF. During setting process, setting indicator will be on. 

 Timer preview:

 Under timer status, press “Delay 1-24hr” button to enter into timer preview. Dual-8 nixie tube displays residual time.

 Cancel timer:

 During timer preview or timer setting process, press “Delay 1 -  24hr” button to cancel timer setting. 

Timer indicator will be off.

6

+

 /      button

Under temperature setting status, after each pressing of “

+

” or “     ” button,temperature will increase or decrease 1°F. 

Temperature setting range: 64~86°F

Under timer setting status, after each pressing of “

+

” or “     ” button, time will increase or decrease 1h.

After timer function is started up, press Delay 1-24hr button to display residual time.

Dual-8 nixie tube defaults to display Fahrenheit temperature. If it needs to display centigrade temperature,
press temperature 

+

 and      buttons simultaneously for 3s. If it needs to display Fahrenheit temperature, repeat

this operation.

Under on status but not timer and temperature setting status, it displays indoor ambient temperature.

Under temperature setting status, it displays set temperature. Under timer setting or timer viewing status,

it displays the time.

7

Display of dual-8 nixie tube

TIMER ON:

 Press this button under off status can set TIMER ON. Timer indicator will be on. Dual-8 nixie tube displays

timer value. After each pressing   of “

+

-

” or “     ” button, time will increase or decrease 1h. If hold “

+

” or “     ”

-

button, time will change quickly after 2s. Loose the button until reaching to

 into timer status.

 TIMER OFF:

 Press this button under on status can set TIMER OFF. Time r   indicator will be on. Dual-8  nixie tube 

displays timer value. After each pressing 

   of “

+

” or “     ” 

-

button, time will increase or decrease 1h. If hold “

+

” or “     ”

-

 

   button, time will change quickly after 2s. Loose the button until reaching to 

   into timer status.

Note:

 

Time setting range: 1-24h

-

-

-

-

Summary of Contents for GJC05BT-A6NMNF1A

Page 1: ...hank you for choosing our product Please read this Owner s Manual carefully before operation and retain it for future reference If you have lost the Owner s Manual please contact the local agent or vi...

Page 2: ...GJC05BT A6NRNE1A GJC05BT A6NMNF1A GJC05BT A6NRNF1A GJC05BT A6NMNF1B GJC05BT A6NRNF1C GJC06BT A6NRNF1A GJC06BT A6NRNF1B...

Page 3: ...problems in the chart of troubleshooting tips If you review our chart of Troubleshooting Tips first you may not need to call for service at all The air conditioner is not intended for use by young chi...

Page 4: ...dren should be supervised to ensure they are away from the appliance This appliance can be used by children aged from 8 years and above and Children shall not play with the appliance Cleaning and user...

Page 5: ...2 has got very good thermodynamic features which lead to a really high energy efficiency The units therefore need a less filling WARNING Should repair be necessary contact your nearest authorized Serv...

Page 6: ...appliance shall be stored in a room without continuously operating ignition sources for example open flames an operating gas appliance or an operating electric heater Do not pierce or burn Be aware t...

Page 7: ...ances d n a r e k a e r b t i u c r i c l l a t s n i s y a w l A a dedicated power circuit Do not open the unit during operation Do not use the power cord near flammable gas or combustibles such as g...

Page 8: ...i d r o c r e w o p h c t i w s r e w o p n i a m e h t f f o n r u T r o f t i n u e h t g n i s u t o n n e h w e m i t g n o l a Always insert the filters securely Clean the filter once every two w...

Page 9: ...Safety Precautions 5 Operation of Current Device Please contact Customer Service with a new cord please contact Customer Service NOTICE WARNING...

Page 10: ...S Unplug air conditioner before servicing Use two or more people to move and install air conditioner Plug into a grounded 3 prong outlet Do not remove ground prong Do not use an adapter Do not use an...

Page 11: ...ushed the electronics detect leakage current and power will be disconnected in a fraction of a second To test your power supply cord 1 Plug power supply cord into a grounded 3prong outlet 2 Press RESE...

Page 12: ...with opening widths of 23 to 36 inches 584 mm to 914 mm FIG 1 lower sash must open sufficiently to allow a clear vertical opening of 14 1 2 inches 368mm Side louvers and the rear of the AC must have...

Page 13: ...vel about a 1 3 bub ble will be the correct case slant to the outside See FIG 5 FIG 6 2 Once the air conditioner is placed extend both the left and right accordion panels to the width of the window Ac...

Page 14: ...ff and disconnect the power cord 2 Remove the sash seal from between windows and unscrew sash lock 3 Remove the screws installed through the frame and frame lock 4 Close slide the side panels into fra...

Page 15: ...tatus Starting Your Air Conditioner Digital Control Note If no button press for 2 minutes all LED brightness is off directly 1 Power button 2 Mode button 3 Fan Speed button 4 Sleep button 5 Delay 1 24...

Page 16: ...r each pressing of or button temperature will increase or decrease 1 F Temperature setting range 64 86 F Under timer setting status after each pressing of or button time will increase or decrease 1h A...

Page 17: ...is a general use remote controller it could be used for the air conditioners with multifunction For some function which the model dosen t have if press the corresponding button on the remote controll...

Page 18: ...me will increase or decrease 1h As for electric heating mode when setting time within 10hours after each pressing or button time will increase or decrease 0 5h when setting time is among 10 24h after...

Page 19: ...oner has the louver type described below Auger Type Rotate the Auger Wheels until the desired Left Right direction is obtained Thermostat The thermostat is used to set the desired room temperature whe...

Page 20: ...oner during the winter remove it carefully from the window according to the installation instructions Cover it with plastic or return it to the original carton Care and Cleaning Normal Sounds Repairin...

Page 21: ...t the blast of cold air you may be accustomed to from older units but this is not an indication of lesser cooling capacity or efficiency Refer to the efficiency rating EER and capacity rating in BTU h...

Page 22: ...concerns at GREE customer experience center Jinji West Rd Qianshan Zhuhai China Please include a daytime phone number in your correspondence Please record your model s information Whenever you call to...

Page 23: ...nt s manufac turer Installation notes 2 Leak test is a must after installation Maintenance notes 1 Check whether the maintenance area or the room area meet the requirement of the nameplate It s only a...

Page 24: ...h N2 gas e cutting or welding f carry back to the service spot for welding 2 The refrigerant should be recycled into the specialized storage tank and it s well ventilated Filling the refrigerant fer e...

Page 25: ...ing operation 1 Be familiar with the device and its operation 2 Cut off power supply 3 Make sure the following items before proceeding If needed mechanical operation device shall be convenient for the...

Page 26: ...normally shall be prepared The hose shall adopt removable connector without leakage for connection and keep it in good status Check if the recycling device is in normal status before using it and if i...

Page 27: ...600005061150 GREE ELECTRIC APPLIANCES INC OF ZHUHAI Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 Tel 86 756 8522218 Fax 86 756 8669426 E mail gree gree com cn www gree com...