Wiring
With a Multi indoor unit, install as described in the installation manual supplied with the Multi outdoor unit.
Live the sensor securing plate, remove the front metal plate cover, and connect the branch wiring to the terminal block.
1)Strip wire ends (15mm)
2)Mach wire colours with terminal numbers on indoor and outdoor unit’s terminal blocks and firmly screw wires to
the corresponding terminals.
3)Connect the earth wires to the corresponding terminals.
4)Pull wires to make sure that they are securely latches up, then retain wires with wire retainer.
CAUTION
1)Do not use tapped wires, stranded wires, extensioncords, or starburst connections, as they may cause overheating,
electrical shock, or fire.
2)Do not use locally purchased electrical parts inside the product. (Do not branch the power for the drain pump, etc, from
the terminal block.) Doing so may cause electric shock or fire.)
2
7
INSTALLATION INSTRUCTIONS
Installation of indoor unit
Outdoor unit
Indoor unit
Firmly fix the wires with the
terminal screws
Firmly fix the wires with the
terminal screws
When wire length exceeds 10m,
use 2.0mmdiameter wires
N(1) 2
3
Terminal block
Electrical
component
box
Wire retainer
Use the specified wire type.
Shape wires so
that the front metal
plate cover will fit
securely.
Firmly secure wire
retainer so that
wires sustain no
external stress.
Sensor securing plate
Front metal
plate cover
Summary of Contents for GEH09AA-K6DNA1F/I
Page 2: ...GEH09AA K6DNA1F I GEH12AA K6DNA1A I GEH18AA K6DNA1F I...
Page 39: ......
Page 40: ...66129931224...
Page 42: ......
Page 43: ...GEH09AA K6DNA1F O GEH12AA K6DNA1A O GEH18AA K6DNA1F O...
Page 67: ......
Page 68: ...66129931225...
Page 70: ...GEH09AA K6DNA1F I GEH12AA K6DNA1A I GEH18AA K6DNA1F I...
Page 108: ...GEH09AA K6DNA1F O GEH12AA K6DNA1A O GEH18AA K6DNA1F O...
Page 134: ...GEH09AA K6DNA1F I GEH12AA K6DNA1A I GEH18AA K6DNA1F I...
Page 170: ......
Page 171: ......
Page 174: ...GEH09AA K6DNA1F O GEH12AA K6DNA1A O GEH18AA K6DNA1F O...