6
NOTE:
• The description for installation is for the standard vertical
double hung window.
• If you need to install the air conditioner in a narrow
window, you may not need to use the
Flexible Screen
sub-assembly. Please refer to requirement of window
size for details.
• All parts must be secured to firm wood, masonry, or
metal.
• The electrical outlet must be within reach of the
power cord.
STORM WINDOW
A storm window frame will not allow the air conditioner to tilt
toward the outside, and it will prevent the unit from properly
draining. To adjust for this, attach a piece of wood (not
included) to the window sill.
Wood Piece:
Width: 5.1 cm (2”)
Length:
Long enough to fit inside the window frame
Thickness:
To determine the thickness, place a piece of
wood on the window sill to make it 1.3 cm (1/2”) higher than
the top of the storm window frame or vinyl frame. Attach
securely with nails or screws (not included).
Storm
window
Frame
5.1 cm (2”)
piece
of wood
1.3 cm (1/2”)
INSTALLATION INSTRUCTIONS
Where to Install the Unit
• Ensure there is no obstruction near the air-inlet or air-outlet.
• Select a window where the condensation water can be dispersed easily out the back
of the unit and won’t affect others.
• The window should be able to withstand the weight of the unit.
• Select a window where noise and outflow air emitted by unit will not affect others.
• Select a window out of reach of children and animals.
W: 57.1 cm – 96.7 cm (22.5” – 38.1”)
H: 34.3 cm (13.5”) min