Wall Mounted Type
Fan Coil Unit Service Manual
26
4�10 E-Heater
“
E-heater
” Function: Under the “
Heat
” mode, the heating efficiency can be improved greatly by activating
the auxiliary electric heater.
How to active the “
E-heater
” function: Under the “
Heat
” mode, press the “
Function
” key to go to the setting
state with the symbol“
” flashing, after that, press “
Enter/Cancel
” to make a confirmation and then the
symbol will stop flashing.
How to deactivate the “
E-heater
” function: When the “
E-heater
” function is activated, press the“
Function
”
key to go to the setting state of the “
E-heater
” function with the symbol“
”flashing, after that, press the “
Enter/Cancel
” key to deactivate this function and then the symbol“
”will disappear.
See Fig. 20 for how to activate the “
E-heater
” function.
Press “
Function
” to go
to the setting status
When the “
E-heate
r”
function is not activated
Press “
Enter/cancel
” to
activate the “
E-Heater
”
function
Fig. 20 How to Activate the “
E-heater
” function
See Fig.21 for how to deactivate the “
E-heater
” function.
When the “
E-heater
”
function is activated
Press “
Function
” to go to
the setting status
Press “
Enter/cancel
” to
dectivate the “
E-Heater
”
function
Fig.21 How to Deactivate the “
E-heater
” Function
NOTE:
①
The “
E-heater
” function is unavailable under the “
Cool
”, “
Dry
” or “
Fan
” mode and the symbol “
”
will not be displayed on the LCD under those modes.
②
When the unit is switched to the “
Heat
” mode, the default status of the “
E-heater
” function is “
On
”.
4.11 Blow
“
Blow
” Function:It is intended to dry the moisture inside the evaporator after the unit is turned on to prevent
mould growing there.
How to activate the “
Blow
” function:Under the “
Cool
” and “
Dry
” mode, when the “
Blow
” function is not
activated, press the “
Function
” key to go to the setting state with the symbol“
”flashing, and then press the
key “
Enter/Cancel
” to make a confirmation.
How to deactivate the “
Blow
” function:When the unit is “
On
” and the “
Blow
” function is activated, press “
Function
” function to go to the setting state with the symbol “
”
flashing, and then press the “
Enter/Cancel
”
key to deactivate this function.
Summary of Contents for FP-102BA2/B-D
Page 1: ...WALL MOUNTED TYPE FAN COIL UNIT SERVICE MANUAL GC201411 I...
Page 3: ...1 Wall Mounted Type Fan Coil Unit Service Manual PRODUCT PRODUCT...
Page 14: ...Wall Mounted Type Fan Coil Unit Service Manual 12 CONTROL CONTROL...
Page 33: ...31 Wall Mounted Type Fan Coil Unit Service Manual INSTALLATION 31...
Page 39: ...37 Wall Mounted Type Fan Coil Unit Service Manual MAINTENANCE...
Page 67: ...JF00300236...