7.Disassemble Axial Flow Fan
Use a spanner to loosen the
holding
nut
to r
emove the
axial flow fan
Holding nut
A
xial Flow Fan
8.Disassemble Outdoor Motor
Screw off the four tapping screws fixing the motor,
pull out the motor lead-out cable plug and remove
the motor. Screw off the two tapping screws fixing
the motor support, and pull the motor support
upward
s
to remove it.
Motor
Screw Fixing the Motor
Motor Cable
Motor Support
Fixing Screw
9.Disassemble 4-Way Valve
Screw off the holding nut of the 4-way valve coil and
remove the coil. Use wet cotton cloth to wrap the
4-way valve, unsold the four soldering points
connecting the 4-way valve, and remove the 4-way
valve. Be quick during the unsoldering process,
pay attention to keep the wrapping cloth wet and
do not allow the soldering flame to burn the compressor
lead-out cable. (caution: only after discharging all freon).
4-way valve
soldering point
Operating Procedures / Photos
37
Summary of Contents for Cooling Bay GVCN18AANK1A1A
Page 2: ...Model Remarks 36K 48K outdoor unit...
Page 15: ...3 Air outlet Component Name Cooling Bay Series...
Page 20: ...5 Electrical Diagram...
Page 21: ...Cooling Bay Series...
Page 47: ...8 Exploded View and Components and Parts List Exploded View of Indoor Unit Cooling Bay Series...
Page 49: ...Exploded View of Indoor Unit Cooling Bay Series...
Page 51: ...Exploded View of Indoor Unit Cooling Bay Series...
Page 58: ...Exploded View of Outdoor Unit...
Page 61: ...Exploded View of Outdoor Unit Cooling Bay Series...
Page 65: ...Exploded View of Outdoor Unit Cooling Bay Series...
Page 68: ...Exploded View of Outdoor Unit...