GREE U-Match 5 SERIES UNIT SERVICE MANUAL
189
5.4
18.6
5.4
27.8
5.4
250
5.6
20.0
5.6
29.9
5.6
269
5.8
21.5
5.8
32.1
5.8
289
6.0
23.0
6.0
34.3
6.0
309
6.2
24.5
6.2
36.6
6.2
330
6.4
26.1
6.4
39.1
6.4
351
6.6
27.8
6.6
41.5
6.6
374
6.8
29.5
6.8
44.1
6.8
397
7.0
31.3
7.0
46.7
7.0
420
7.2
33.1
7.2
49.4
7.2
445
7.4
34.9
7.4
52.2
7.4
470
7.6
36.9
7.6
55.1
7.6
496
7.8
38.8
7.8
58.0
7.8
522
8.0
10.8
8.0
61.0
8.0
549
4. Operation Tools
The following tools will be used: 1) Liquid-level gauge; 2) Screwdriver; 3) Electric driven rotary hammer; 4) Drill; 5) Pipe expander;
6) Torque wrench; 7) Open-end wrench; 8) Pipe cutter; 9) Leak detector; 10) Vacuum pump; 11) Pressure gauge; 12) Universal
meter; 13) Hexagon wrench; 14) Tapeline.