Installation and Maintenance
Service Manual
11. Removal Procedure
11.1 Removal Procedure of Indoor Unit
Caution: discharge the refrigerant
completely before removal.
Step
Procedure
1. Remove filter
Under on status, press clean button on the remote
controller to enter into clean mode.
Once the air guide louver has been pushed to the
maximum position, please cut off the power.
Hold the handle on the filter, pull it upwards to let
the clasp at the top part of the filter loose, push it
forwards and then the filter can be pulled out.
2. Remove horizontal louver
Hold the clasp spring at the left side of the
connection rod of swing blade, pull the connection
rod to the right side to get loose the hook of
connection rod used for fixing the swing connection
rod.
Air guide louver sub-assy
clasp
Filter
Clasp spring