14
Technical Information
Outdoor
Unit
Outdoor Unit Model
GWH24AFE-K6DNA2I/O
GWH24AFE-K6DNA2I/O
Outdoor Unit Product Code
CB363W04100
CB363W04101
Compressor Manufacturer
ZHUHAI LANDA COMPRESSOR
CO,LTD.
ZHUHAI LANDA COMPRESSOR
CO,LTD.
Compressor Model
QXFS-M180zX170
QXFS-M180zX170
Compressor Oil
FW68DA or equivalent
FW68DA or equivalent
Compressor Type
Twin Rotary
Twin Rotary
Compressor LRA.
A
35
35
Compressor RLA
A
3.5
3.5
Compressor Power Input
W
1610
1610
Compressor Overload Protector
KSD115ºC HPC 115/95U1
KSD115ºC HPC 115/95U1
Throttling Method
Electron expansion valve
Electron expansion valve
Set Temperature Range
ºC
16~30
16~30
Cooling Operation Ambient
Temperature Range
ºC
-15~50
-15~50
Heating Operation Ambient
Temperature Range
ºC
-15~30
-25~30
Condenser Form
Aluminum Fin-copper Tube
Aluminum Fin-copper Tube
Condenser Pipe Diameter
mm
Φ7
Φ7
Condenser Rows-fin Gap
mm
2-1.4
2-1.4
Condenser Coil Length (LXDXW)
mm
839×38.1×616
839×38.1×616
Fan Motor Speed
rpm
800
800
Fan Motor Power Output
W
60
60
Fan Motor RLA
A
0.65
0.25
Fan Motor Capacitor
μF
/
/
Outdoor Unit Air Flow Volume
m
3
/h
3600
3600
Fan Type
Axial-flow
Axial-flow
Fan Diameter
mm
520
520
Defrosting Method
Automatic Defrosting
Automatic Defrosting
Climate Type
T1
T1
Isolation
I
I
Moisture Protection
IPX4
IPX4
Permissible Excessive Operating
Pressure for the Discharge Side
MPa
4.3
4.3
Permissible Excessive Operating
Pressure for the Suction Side
MPa
2.5
2.5
Sound Pressure Level (H/M/L)
dB (A)
59
59
Sound Power Level (H/M/L)
dB (A)
70
70
Dimension(WXHXD)
mm
958X660X402
958X660X402
Dimension of Carton Box (LXWXH)
mm
1029X453X715
1029X453X715
Dimension of Package(LXWXH)
mm
1032X456X737
1032X456X737
Net Weight
kg
41.5
41.5
Gross Weight
kg
46
46
Refrigerant
R32
R32
Refrigerant Charge
kg
1.5
1.5
Connection
Pipe
Connection Pipe Length
m
5
5
Connection Pipe Gas Additional Charge g/m
40
40
Outer Diameter Liquid Pipe
1/4"
1/4"
Outer Diameter Gas Pipe
5/8"
5/8"
Max Distance Height
m
10
10
Max Distance Length
m
25
25
Note: The connection pipe applies metric diameter.
The above data is subject to change without notice. Please refer to the nameplate of the unit.