ELECTRICAL REQUIREMENTS

1.

The air conditioner must be grounded ; it is equipped with a LCDI 

(Leakage Current Detection and Interruption) power cord and plug 
This feature will circuit trip the electrical power source if the nominal 
current leakage between the cord shield and either load conductor 
exceeds a predetermined value.  The cord will remain out of power 
until the device is manually reset.  This is intended to protect against 
electric shock and to reduce the risk of a fire in the power cord or 
combustible materials nearby. The cord shield is not grounded and 
must be considered a shock hazard if exposed.  The cord shield 
must not be connected to ground or to any exposed metal.

2.

Do not cut or bypass the plug ground prong. If you do not have a grounded outlet available 

near the air conditioner, have one installed by a qualified electrician.

3.

The power supply rated voltage is ± 6%.

4.

Do not connect the unit to an outlet being used by other appliances; ideally, connect to a single 

grounded 15A circuit (time-delay fuse or circuit breaker).

5.

If the power cord or plug is damaged, call SUNRISE TRADEX Customer Service.

• Electrical ratings of the air conditioner are detailed on the rating plate on the back of the unit.
• Basic electrical requirements are listed hereafter. Please make sure to check the following before    

installing and connecting your unit.

INSTALLATION 

5

Casters

Drain hose

Cap

Clamp

Rear grille

PREPARING THE AIR CONDITIONER
F

IXING THE CASTERS

(Some models only)

To avoid the risk of causing damages to the air conditioner,
you must install the casters before using the appliance. 

1.

Open the accessory bag and take the 4 casters out.

2.

Recline the unit, one side at a time, to insert the unit into 

the base holes. Do not recline the unit more than 45°
from the ground.

3.

Screw the casters into the base threaded holes.

I

NSTALLATION OF THE DRAIN HOSE

(Some models only)

You must fix the drain hose before operating the unit.  

1.

Take out the drain hose, the hose cap and the clamp

from the accessory bag. 

2.

Insert the drain hose into the drain hole on the lower 

back of the unit. Make sure that the drain hose is 
correctly inserted into the drain hole.

3.

Put the hose cap on the free end of the drain hose.

4.

Fix the drain hose on the rear grille with the clamp.

Summary of Contents for 13-04582

Page 1: ...E AIR CONDITIONER Please read the following owner s manual before using this air conditioner Keep this manual along with your proof of purchase in a safe place for future reference MODEL 13 04582 0022...

Page 2: ...e 6 Wall installation 6 Installation by window type 7 CONTROL PANEL AND LCD DISPLAY Control panel 8 LCD display 8 UNIT OPERATION Cooling 9 Dehumidifying 9 Fan 9 Auto Mode 10 Sleep Mode 10 Setting the...

Page 3: ...rea with possible gas leakage or in an explosive atmosphere near a bath shower enclosure swimming pool or any other steamy and wet areas in a greenhouse 6 Do not apply insecticides or any other flamma...

Page 4: ...ectric cord hot air outlet upper air outlet handle lower air inlet grille control panel lower air inlet grille water drain hole INSTALLATION KIT square hose adaptor to unit air exhaust hose window adj...

Page 5: ...uit breaker 5 If the power cord or plug is damaged call SUNRISE TRADEX Customer Service Electrical ratings of the air conditioner are detailed on the rating plate on the back of the unit Basic electri...

Page 6: ...air conditioner and the hot air outlet 2 Drill a hole of 13 3 cm 5 1 4 on the exterior wall The hole must be 40 to 130 cm 16 to 50 above the floor Figure C 3 Fix the external end of the exhaust hose...

Page 7: ...window kit to form a tight seal 3 Attach the exhaust hose adaptor to the window slider kit the adaptor tabs will lock into place the adaptor to the window kit INSTALLATION 7 NOTE Using the window sli...

Page 8: ...he fan speed cannot be adjusted To set temperature in cooling or auto mode To set the time of hours when the timer is on Sets the air conditioner in SLEEP mode automatic shut off SLEEP In sleep mode a...

Page 9: ...D to set fan speed at LOW MEDIUM or HIGH each speed level is identified by an icon lighting up when selected When the room temperature is slightly warmer than the set temperature the compressor starts...

Page 10: ...ff in less than 7 hours use the TIMER button to adjust the delay by 1 2 hour slot up to 7 hours maximum The LCD display will show the set time 5 To cancel press again the SLEEP button until the SLEEP...

Page 11: ...may need to control your air conditioner from a distance All operational functions of your remote as well as message and icon identification are described in the next 2 pages After entering a mode or...

Page 12: ...n FAN and choose the speed HIGH M Medium or LOW each speed icon will flash Press on SEND a beep will confirm transmission and the speed icon will stop flashing TO SET TEMPERATURE Press on C or C to se...

Page 13: ...ME CLOCK Press on TIMER until the TIME icon flashes the LCD screen will display the current time To change the time press on Hr the hour icon will flash set the hour then press on Min to set the minut...

Page 14: ...the unit when the water pan is full 2 Unclamp the drain hose from the rear grille 3 Place a 2 L container under the drain hose 4 Remove the cap from the drain hose The condensate water will drain out...

Page 15: ...re are animals around If the filter is damaged or used contact SUNRISE TRADEX Customer Service STORAGE Turn the unit off and unplug Drain all condensate water from the unit Turn the unit to fan mode f...

Page 16: ...t is not working properly The water tank is full Is the air filter dirty Is the air conditioner leveled Is the drain hose and the hose cap correctly installed SOLUTION 1 Plug in correctly 2 Change the...

Page 17: ...listed hereafter are for references only Please see technical data on your air conditioner unit rating plate CUSTOMER SERVICE Contact SUNRISE TRADEX CORP Customer Service for Replacement parts Technic...

Page 18: ...f the unit enclosure or to other outer features caused by wear 4 The filter 5 Damage caused by repairs or modifications to the air conditioner made by any person not duly authorized by SUNRISE TRADEX...

Reviews: