23
Maintenance
Service Manual
Procedure
Step
spots weld
condenser and evaporator assembly
8.Remove the handle
9.Remove evaporator and condenser sub-assy
10.Remove support rod
11.Remove electric box sub-assy
Twist off the screws, remove the cover
and move the handle along the horizontal
direction and then remove it.
Twist off the screw behind the condenser,
unsolder the soldering joint connected to
the condenser and evaporator respectively
and then remove the evaporator and
condenser sub-assy (Note: Release all the
refrigerant completely before soldering)
Twist off the 2 screws used for fixing the
supportrod and then take out the support
rod.
Pull out the power cord connected to
the main board and wires on liquid level
switch and compressor, twist off the
screws on electric box and then remove
the electric box sub-assy.
screws
screws
electric box sub-assy
support rod
screws
screw
handle