Procedure
Step
10.Remove motor and cross flow blade
Adjust the position of conncetion pipe on
evaporator up wards to remove it.
Remove the screws fixing motor clamp and
then remove the motor clamp.
①
Remove the screws at the connection
place of cross flow blade and motor; lift
the motor and cross flow blade upwards to
remove them.
②
Remove the bearing holder sub-assy.
③
Remove the screw fixing step motor and
then remove the step motor.