Operational and Maintenance Manual G11 Series
Fig. 53 Lub oil filter head
Fig.54 Lub oil filter head
•
Check belt tension and make adjustments,
if required.
Fig. 55 Belt tension
•
Confirm the battery condition.
•
Confirm that all necessary safety guards
are in place.
•
Confirm if all safety precautions have been
taken.
•
Confirm that the electrical breaker is in
OFF position.
Note:
Sudden loading of the engine from 0 to 100% of
rated load is to be avoided for turbocharged and
turbo after cooled engine. In turbo after cooled
engines sudden loading is limited to 45 to 50 % of
the rated power as per ISO 8528. Never try to start
the engine on load.
•
Start the engine and run on no load for 5 to
10 minutes.
•
Observe abnormalities like noise, vibration,
rattling brackets, leakages, etc.
•
Check oil pressure. Confirm that all the
meters are working.
•
Confirm that everything is OK and then
slowly load the engine.
•
The engine is provided with a battery-
charging alternator.
•
During the normal running of the engine,
the charging lamp should be OFF.
If the battery-charging lamp turns ON during
engine running, it is an indication that the battery is
not getting charged. Check the circuit and take
corrective actions.
6.2.3 In case of Key start:
•
For starting the engine turn the key from
“ÓFF” to “ON” This will light up the battery
voltage gauge and the pilot lamp will light
up.
•
Turn the key further. Engine will rotate,
when the engine picks up speed, release
the key.
26