25
Twin Fan Hydraulics
Hydraulic hoses serve the fans and must be properly
connected for the fans to operate in the correct
direction, at recommended speeds, and without
damage.
(1) Always connect the case drain hose first.
The case drain hose protects the outer seal of
the hydraulic motor. It is small line to the hitch,
supplied with a specialize low-seep flat-face case
drain quick disconnect. Pressure spikes during
motor operation and pressure cycles due to
temperature change are bled off by the case
drain.
Motor Seal Damage Risk
Do not apply pressure to the case drain line.
Do not change the special quick connector.
A restricted or sealed case drain line will
promptly result in motor seal damage.
(2) Pressure line from tractor retract.
(3) Return to tractor along right tool-bar.
(4) Pressure line from tractor retract fold/bulk
value.
(5) Return from delivery fan to meter pressure
fan.
(6) Case drain from meter pressure fan to
delivery fan motor.
(7) Return bypass to motor tank port.
The fan hydraulic circuits include a check valve
which provides a relief path for oil at motor shutoff.
The resulting low fan rpm provides indication of
reverse connection.
If a reversed fan is suspected, observe during shutoff
since the direction of motor is easier to see at lower
rpm rates.
Initial startup is nearly instantaneous,
making observing at startup difficult.
If a fan is connected in reverse, it may not run at all
due to no oil source at the return connection. If oil is
present, oil bypass at the check valve prevents the
fan from reaching operating rpms. A reversed fan is
incapable of providing sufficient air flow for planting.
Fan Operation
Use the tractor remote hydraulic valve flow control to
set fan speed. Always start the fans with a low flow
setting. Monitor fan rpm with the seed monitor.
Gradually bring fans up t o the recommended initial
rpm. The recommended initial fan speed is 2800
rpm.
The monitor console can report meter pressurization.
There is also a Magnehelic air pressure gauge.
These two readings should not disagree by more
than a few tenths of an inch.
The Seed Rate manual provides initial
values for meter pressurization. Normal
readings are in the 4/5 to 4 inches (2 to 10
cm) H
2
O and vary considerably with crop.
If the fans are running at suggested rpm or the
meters are not getting seed, the fans may be running
backward. Reverse the inlet/return lines at the hitch.
Fertilizer (Option)
Agricultural Chemical Hazard
Some chemicals will cause serious burns,
lung damage, and death. Avoid contact
with skin or eyes. Avoid prolonged
breathing of chemical fumes. Wear
respirator and other protective equipment
as required by chemical manufacturer.
Seek medical assistance immediately if
accident occurs. Know what to do in case
of an accident.
68198
1
3
4
6
2
5
7
!
i
i
!
Summary of Contents for Yield-Pro PL5800
Page 8: ...Great Plains 411 474M 12 17 2019 viii PL5800 Planter Table of Contents Index...
Page 14: ...Great Plains 411 474M 12 17 2019 6 PL5800 Planter Table of Contents Index Safety Information...
Page 59: ...Table of Contents Index...
Page 75: ...Table of Contents Index...
Page 99: ...Table of Contents Index...
Page 103: ...Table of Contents Index...
Page 105: ...Table of Contents Index...
Page 107: ...Great Plains 411 474M 12 17 2019 100 PL5800 Planter Table of Contents Index LIMITED WARRANTY...
Page 110: ...Table of Contents Index...
Page 111: ...Great Plains Mfg 1525 E North St P O Box 5060 Salina KS 67402...