2018-07-24
401-312M
3PYP
Maintenance and Lubrication
88
Seed Clean-Out
Cleaning Out Air System
1.
Shut off sliding door at bottom of seed box or bean
hopper.
2.
Place a pan or tarp under the manifold to catch the
seed.
3.
Open manifold door to empty seed from manifold.
If needed, additional access doors are provided.
4.
Shut door under manifold.
5.
Close all Y-tubes.
6.
If seed meters were cleaned out first, leave the
hoses disconnected at the meters.
7.
Turn on the air fan and let it run.
8.
Start at one end of planter and place a bucket under
the hose or meter to catch the seed. If hose is
connected, open clean-out door.
9.
Open the Y-tube gate feeding that meter. Let the air
blow seed out. Keep the meter open for a couple of
minutes after the seed stops blowing out.
10. Close the Y-tube gate feeding that meter. Close the
meter clean out door.
11. Repeat procedure on the next meter in line. Continue
with this procedure until you have reached the
opposite end of the planter.
Cleaning Out Meters
1.
Place a bucket or pan under meter to catch any seed
during clean-out.
2.
Slide the retaining ring up and remove seed hose.
Singulating Meter
3.
Pull clean-out door away from the opening and allow
seed to fall.
4.
Remove the seed meter wheel for thorough cleaning.
Refer to “
Seed Meter Setup and Adjustment
page 72 for more information.
Finger Pickup Meter
5.
Pull clean-out door away from the opening and allow
seed to fall.
Figure 105
Cleaning: Y-Tubes
22843
Figure 106
Disconnect Seed Tube
22883
Figure 107
Singulating Clean-out Door
22885
Figure 108
Finger Meter Clean-out Door
21920