3N-4010F, 3N-4010HDF, and 3N-4020F
Troubleshooting
91
2019-03-08
196-359M
Point Row Troubleshooting
Hydraulic Drive Troubleshooting
Drive will not rotate:
(see Troubleshooting Flow Chart and Electronics
Overview, page 95 and page 96)
1. Check cab console:
a. No power to cab console - check with voltmeter.
b. Upper line (set) is visible but no lower line (out
rate and speed) on display: move to
Communication troubleshooting below.
c. 1 or 10 amp fuse on power cable may be blown.
d. Engage button is not on - check to see if green
indicator light is on.
e. Use Cab Console Power Tester (p/n 27857) to
check power out of cab console. Install tester on
round 7-pin power/comm cable from cab
console. Turn drive on. Green LED shows power
to external controller. Red LED shows power to
solenoid. If LED lights are not lit, double-check
power and connections; replace cab console if
needed.
2. Check communication between cab console and
drive:
a. Check to see if power and communication cable
(main harness) is properly connected.
b. If no lower line on cab console appears (speed
and output rate), and drive will not rotate in
calibration mode, use Cable Continuity Tester
(p/n 27859) to test power and communication to
external controller.
TO PREVENT DAMAGE TO COMPONENTS, DISCONNECT
POWER/COM CABLE FROM CAB CONSOLE AND
EXTERNAL CONTROLLER BEFORE INSTALLING THIS
TESTER.
Install 4-pin test plug on end of 4-pin
power/comm cable before powering the Cable
Continuity Tester - remove before reattaching
power/comm cable directly to cab console.
c. If Cable Continuity Tester shows power is getting
to external controller, turn power off and remove
Cable Continuity Tester and 4-pin test plug from
ends of power/comm cable. Reattach
Seed cup sprockets locked
up or seed drive shaft twisted
Foreign matter lodged in seed cup sprockets. Clean out seed cup sprockets.
Build-up of dried liquid insecticide in seed
cups.
Remove build-up by disassembling each seed
cup and scraping the foreign substance from
turning surfaces.
Problem
Cause
Solution
no seed
metering, all
rows
fuse blown
Check fuse. Correct underly-
ing fault before replacing
fuse.
height switch
not tripping
Check adjustment of height
switch.
no metering,
one section
clutch failure
Lock-up clutch until repaired
or replaced.
shearing
Replace
1
4
-20 bolts and
1
4
in
roll pins in clutch assembly.
seed rate low
or uneven
lubricant in
clutch
Disassemble and degrease
clutches.
meters always
on
CAL mode on
Move Master switch handle
from CAL to ON.
height switch
always on
Check adjustment of height
switch.
Problem
Cause
Solution