15
Grease Guardian Controller: Cycle Programming
Screen 3 optimises the cycle duration
Low Skim
DEFAULT
= 10 mins skimming/cycle
Medium Skim = 20 mins skimming/cycle
High Skim = 30 mins skimming/cycle
Select a mode by pressing
LOW SKIM: skims for 10 mins only. (1 skim)
MEDIUM SKIM : skims 10 minutes then pauses for 5 mins
before a further 10 minute skim repeat. (total 2 skims)
HIGH MODE: skims 10 minutes then pauses for 5 mins,
skims 10 minutes, pauses 5 then skims 10. (total 3 skims)
B
Setting a Cycle. Choose a Skim Mode. (Screen 3)
Setting a Cycle. Heater Setting. (Screen 4)
-
+ OK
B
The default setting inside screen 4 is:
Heater set to ON, with a preheat of 30 minutes.
The Heater can be switched off completely by tog-
gling “B”
When the heater is set to ON the full range for
preheat is 5-60 minutes which is adjustable
using the (see intro page on adjusting
timer values)
Setting a Cycle. Weekday Settings (Screen 5)
In screen 5 there are 12 programable states for set-
ting the daily cycles to ON /OFF for specific week
days.
Simply advance
through 12 options
by pressing:
B
A
ESC
Screen 1
A
ESC
Screen 1
A
ESC
Screen 1
ESC
Screen 1
A