50
M_LS100IQ EX Energy_EN_C
Operating instructions for the machine
Temperature alarm function
When a temperature alarm is triggered, the error code and the temperature are displayed on-screen
simultaneously. To stop the audible alarm signal, press one of the controller keys. The alarm remains displayed
until its cause has been eliminated.
Error
Meaning
E1
Maximum ambient temperature exceeded
E2
Maximum water temperature exceeded
E3
Water temperature below the minimum
E4
Malfunction of the ambient temperature sensor
E5
Malfunction of the water temperature sensor
Flow alarm function
When an alarm is triggered, the red indicator light is illuminated and an audible signal is sounded. The green
indicator light goes out.
Indicator(s)
Status
Normal flow
indicator light
(Green)
Flow alarm indicator
light (Red)
Audible alert
Cooling water circulation loop obstructed
Off
On
Yes
Insufficient water alarm
Off
On
Yes
Malfunction of the water circuit pump
Off
On
Yes
General parameters
The parameters of the industrial chiller supplied with the ENERGY machines are preset
(Initial setup). It is not necessary to change these parameters.
Press the (SET) button in normal mode. The red indicator light flashes. This indicates that the controller is in
parameter setting mode.
• In constant temperature control mode, the screen displays the value of the set temperature (parameter
F0).
•
In intelligent control mode, the screen displays the temperature difference between that of the water and
that of the ambient air (parameter F1).
Use the arrow keys to change the parameters.
After modifying the values, press the (RST) button to save and exit. The new parameters become active.
Otherwise, press the (SET) button to exit setting mode without saving the new parameters.
If no button is pressed within 20 second(s), the controller automatically exits parameter setting mode
without saving the modified parameters.