51
20. Specification
Battery Output 1:
Charge currents / power
100 mA to 5.0 A / max. 50 W with internal power supply
100 mA to 5.0 A / max. 50 W with external 12...15V DC power supply
Discharge currents / power
100 mA to 1 A / max. 5 W
Ni-Cd & Ni-MH batteries:
Cell count
1 - 14 cells
Capacity
min. 0,1 Ah to 8,0 Ah
Lithium batteries:
Cell count
1-6 cells
Cell voltage
3,3 V (LiFe), 3,6 V (LiIo) / 3,7 V (LiPo/LiMn)
Capacity
min. 0,05 Ah to 8,0 Ah
Lead-acid / lead-gel batteries:
Cell count
1, 2, 3, 6 cells
Battery voltage
2, 4, 6, 12 V
Capacity
min. 1 Ah
Battery Output 2 and 3:
Charge currents / power
0.1 A to 1.0 A
Ni-Cd & Ni-MH batteries:
Cell count
1 - 8 cells
Capacity
min. 0,1 Ah to 6,0 Ah
Lithium batteries:
Cell count
2 - 3 cells
Cell voltage
3,3 V (LiFe), 3,6 V (LiIo) / 3,7 V (LiPo/LiMn)
Capacity
min. 0,05 Ah to 5,5 Ah
General:
Operating voltage range DC input 11,0 to 15 V
Operating voltage range AC input 100 ~ 240V
Output power overall max.:
50W
Car battery required
12 V, min. 30 Ah
Mains PSU required
12-15V, min. 8,5 A stabilised
1)
No-load current drain approx
0.1 A
balancer connector Output 1:
1...6 NiMH/NiCd/LiPo/LiIo/LiFe cells
balancer connector Output 2, 3:
2...3 LiPo/LiIo/LiFe cells
balancing current Output 1:
NiMH/NiCd: 0.1A, LiPo/LiIo/LiFe: 0.3A
balancer current Output 2, 3:
LiPo/LiIo/LiFe: max. 42mA
Low-voltage cut-off approx
11,0 V
Weight approx.
730 g
Dimensions approx. (WxDxH)
185 x 169 x 55 mm
All data assumes a car battery voltage of 12.7 V.
The stated values are guidelines, and may vary according to battery state, temperature etc.
1 )
When powered by a mains PSU, the charger will only operate correctly if the PSU is suitable in terms of voltage,
stability, maximum load capacity etc. You can avoid problems by using only the PSUs which we specifically recommend.