Sonata Series — Planning and Installation Manual
45
Interfacing to Apex
Output Mapping for the Sonata MADI to AES Outputs from Apex
The MADI outputs of the Apex Router have a fixed channel assignment.
These channels can not be changed or remapped. However, the mode the
Apex router is running can change how the signals are addressed from the
control system.
The MADI outputs on the Apex router are hard wired into blocks or 32 AES
outputs which correspond to the output cards. This means that a set of
B16
AES Pair 16 Right
Input 32
C17
AES Pair 17 Left
Input 33
C17
AES Pair 17 Right
Input 34
C18
AES Pair 18 Left
Input 35
C18
AES Pair 18 Right
Input 36
C19
AES Pair 19 Left
Input 37
C19
AES Pair 19 Right
Input 38
C20
AES Pair 20 Left
Input 39
C20
AES Pair 20 Right
Input 40
C21
AES Pair 21 Left
Input 41
C21
AES Pair 21 Right
Input 42
C22
AES Pair 22 Left
Input 43
C22
AES Pair 22 Right
Input 44
C23
AES Pair 23 Left
Input 45
C23
AES Pair 23 Right
Input 46
C24
AES Pair 24 Left
Input 47
C24
AES Pair 24 Right
Input 48
D25
AES Pair 25 Left
Input 49
D25
AES Pair 25 Right
Input 50
D26
AES Pair 26 Left
Input 51
D26
AES Pair 26 Right
Input 52
D27
AES Pair 27 Left
Input 53
D27
AES Pair 27 Right
Input 54
D28
AES Pair 28 Left
Input 55
D28
AES Pair 28 Right
Input 56
D29
AES Pair 29 Left
Input 57
D29
AES Pair 29 Right
Input 58
D30
AES Pair 30 Left
Input 59
D30
AES Pair 30 Right
Input 60
D31
AES Pair 31 Left
Input 61
D31
AES Pair 31 Right
Input 62
D32
AES Pair 32 Left
Input 63
D32
AES Pair 32 Right
Input 64
Summary of Contents for Sonata Series
Page 8: ...8 Sonata Series Planning and Installation Manual Preface ...
Page 24: ...24 Sonata Series Planning and Installation Manual Regulatory Notices ...
Page 50: ...50 Sonata Series Planning and Installation Manual Section 2 Planning Guide ...
Page 57: ...Sonata Series Planning and Installation Manual 57 DIP Switches ...
Page 66: ...66 Sonata Series Planning and Installation Manual Appendix A Specifications ...