1.

  The  eight  output  HD-SDI  distribution

amplifier (DA) is available with two levels of
monitoring 

sophistication. 

standard

option 

which 

provides 

board 

level

information  such  as  supply  faults  and
minimum  incoming  signal  analysis.  The
enhanced 

monitoring 

option 

adds 

a

comprehensive  incoming  signal  analysis
capability,  including  the  detection  of  CRC
errors  and  identification  of  the  line
standard/frame  rate  of  the  signal  being
distributed. Refer  to  the  
monitor  option  code
on page 2 to identify what monitoring level
is fitted to the DA board.

2.

  The  interface  card  for  the  single  channel

eight 

output 

DA 

contains 

ten 

BNC

connectors 

(see 

following 

page 

for

drawing)  of  which  only  nine  are  actually
required  for  full  operation  (one  IN,  eight
OUT),  the  middle  BNC  not  being  used.  A
dual channel version of the DA card is also
available  (order  number  SHD_SDA2x  S2)
which  contains  two  separate  four  output
amplifiers. A dual channel DA also has a 10
BNC  rear  interface  card  (two  lots  of  1 IN,
four OUT). The only difference between the
rear interface cards for the two types of DA
is  in  the  backpanel  labelling.  Mechanically
these  two  different  types  of  rear  interface
card  are  completely  compatible  with  each
other and can be interchanged between the
different  types  of  DA  board.  Refer  to  the
interface  card  option  code  on  page  2  to
identify  what  interface  card  has  been
supplied  with  the  eight  output  DA  main
board.

CAUTION: 

Confusion 

could 

arise 

if

single/double  channel  rear  interface  cards  are
assigned  to  the  wrong  type  of  DA  board.
Though full functionality will be maintained for
both  types  of  DA,  the  difference  in  labelling
could be misleading if all such occurrences are
not fully documented at a system level.

Summary of Contents for SHDSDA1

Page 1: ...ON TO THIS OPERATION MANUAL 2 SCOPE OF THIS OPERATION MANUAL 3 MODULE DESCRIPTION 3 FEATURES 4 TECHNICAL PROFILE 5 INPUT 5 OUTPUTS 5 INDICATOR LEDS 5 Standard 5 Enhanced 5 ROLLCALL 5 OPTIONS 5 REAR INTERFACE CONNECTIONS 7 REAR INTERFACE NOTATION GUIDE 7 STANDARD INPUT 7 STANDARD OUTPUTS 7 ROLLCALL MENU SYSTEM 8 ROLLCALL MONITORING FEATURES 9 ...

Page 2: ... software programs which are displayed on the screen such as icons screen display looks etc Reproduction or disassembly of embedded computer programs or algorithms is prohibited No part of this publication may be transmitted or reproduced in any form or by any means electronic or mechanical including photocopy recording or any information storage and retrieval system without permission being grant...

Page 3: ...etailed performance information can be obtained via the RollCall interface Two levels of monitoring sophistication are available to the user A standard operational level is available on all boards covering parameters ranging from voltage supply status to the presence of an input signal The optional enhanced monitoring level provides a comprehensive analysis of the incoming HD SDI signal such as CR...

Page 4: ...locked HD SDI data outputs n Can equalise over 100m of cable n Alarm functions for poor quality input signals and device malfunction n Stand alone or RollCall operation n Incoming signal analysis available as an option it includes CRC status Line standard Frame Rate Error rate Note RollCall TM enabled for remote system control monitoring ...

Page 5: ...e time 20 80 Fall time 20 80 Difference 270ps 270ps 100ps Return loss 15dB INDICATOR LEDS Not available to the Operator Standard Power Power supplies valid Fault Board fault Enhanced Monitoring Option CPU Valid CPU activity PLL Lock Output locked to input standard CRC Error Data error Line Indicates line standard Frame Indicates frame rate Prog Int Indicates progressive or interlaced frames RollCa...

Page 6: ...on one IN eight OUT the middle BNC not being used A dual channel version of the DA card is also available order number SHD_SDA2x S2 which contains two separate four output amplifiers A dual channel DA also has a 10 BNC rear interface card two lots of 1 IN four OUT The only difference between the rear interface cards for the two types of DA is in the backpanel labelling Mechanically these two diffe...

Page 7: ...nt and the n is the connection number for that particular rear interface Standard Input Electrical HD SDI Used On SHDSDA1S S1 SHDSDA1E S1 The high definition serial digital electrical input is connected to a 75Ω BNC connector The connector is shown opposite and is labelled H1 on the rear panel Standard Outputs Electrical HD SDI Used On SHDSDA1S S1 SHDSDA1E S1 The high definition serial digital ele...

Page 8: ...sure a range of monitoring information is available via RollCall External Monitoring Description General alarm Input power fault or overcurrent trip or system failure Supply voltage levels Actual voltage levels Board temperature Actual board temperature CRC Status Line Standard Frame Rate Bit error rate Error rate over defined time period ...

Page 9: ...alue in this field is a guide to the strength of equalisation that is being applied to the input signal for longer cable runs The lower the value the less equalisation is being employed It is intended as a guide for troubleshooting the system It should be noted that when an equalisation of 100 is shown it doesn t necessarily mean that the maximum input cable length has been reached As soon as CRC ...

Page 10: ...Record Date Version No Issue No Change Comments 16 06 01 1 1 First draft document Issued 051001 1 2 Edited current feature list Only states features that are present in current release A1 0 000 New issue released 030402 1 3 New monitoring features added New issue released ...

Reviews: