Scope of this Operation Manual

This  is  the  operation  manual  for  the  System  HD  Single  Channel  Distribution  Amplifier  Module.  It  covers  the
modules ordered under the following codes :

SHDSDA1S-S1 – Standard 8 output distribution amplifier with basic reporting.
SHDSDA1E-S1 – 8 output distribution amplifier with enhanced reporting

SHDSDA1S-S1 and SHDSDA1E-S1 Distribution Amplifier, Rear Panel View

Module Description

The  Eight  Output  HD-SDI  Distribution  Amplifier
provides  eight  reclocked  HD-SDI  outputs  from  a
single HD-SDI input.

The electrical high definition serial digital (HD-SDI)
bitstream is input into the distribution amplifier main
board  via  a  75

  BNC  connector  on  a  rear  panel

interface  card.  The  HD-SDI  input  signal  is  then
equalised  and  re-clocked  before  being  split  to
provide  eight  identical  coaxial  HD-SDI  outputs  for
the user via 75

 BNC connectors on the backpanel

of the interface card.

Detailed  performance  information  can  be  obtained
via the RollCall interface.

Two  levels  of  monitoring  sophistication  are
available  to  the  user.  A  standard  operational  level
is  available  on  all  boards,  covering  parameters
ranging from voltage supply status to the presence
of  an  input  signal.  The  optional  enhanced
monitoring 

level 

provides 

comprehensive

analysis  of  the  incoming  HD-SDI  signal  such  as
CRC  error  detection,  line  standard  and  frame  rate
identification.

WARNING…
THE  FRONT  PANEL  OF  THE  UNIT  MUST  NOT
BE  OPENED  BY  THE  OPERATOR.  ACCESS  IS
ONLY  PERMITTED  TO  FULLY  QUALIFIED
INSTALLATION ENGINEERS.

It  is  recommended  that  a  record  is  made  of  the
System HD Order Code for the module in the table
on  the  following  page.  This  will  allow  easy
identification  of  the  monitoring  level  of  the  main
board when referring to this manual at a later date.

Quick guide to order codes:

SHD SDA1 

X

 

X

Dist. Amplifier

Code

Properties

S

Standard reporting

E

Enhanced reporting

Interface card

option code

Interface card supplied with

main amplifier board

1

10 BNC labelled for 8 output

Codes  other  than  those  listed  refer  to  custom
options.

Amplifier

card

Interface

card

Summary of Contents for SHDSDA1

Page 1: ...ON TO THIS OPERATION MANUAL 2 SCOPE OF THIS OPERATION MANUAL 3 MODULE DESCRIPTION 3 FEATURES 4 TECHNICAL PROFILE 5 INPUT 5 OUTPUTS 5 INDICATOR LEDS 5 Standard 5 Enhanced 5 ROLLCALL 5 OPTIONS 5 REAR INTERFACE CONNECTIONS 7 REAR INTERFACE NOTATION GUIDE 7 STANDARD INPUT 7 STANDARD OUTPUTS 7 ROLLCALL MENU SYSTEM 8 ROLLCALL MONITORING FEATURES 9 ...

Page 2: ... software programs which are displayed on the screen such as icons screen display looks etc Reproduction or disassembly of embedded computer programs or algorithms is prohibited No part of this publication may be transmitted or reproduced in any form or by any means electronic or mechanical including photocopy recording or any information storage and retrieval system without permission being grant...

Page 3: ...etailed performance information can be obtained via the RollCall interface Two levels of monitoring sophistication are available to the user A standard operational level is available on all boards covering parameters ranging from voltage supply status to the presence of an input signal The optional enhanced monitoring level provides a comprehensive analysis of the incoming HD SDI signal such as CR...

Page 4: ...locked HD SDI data outputs n Can equalise over 100m of cable n Alarm functions for poor quality input signals and device malfunction n Stand alone or RollCall operation n Incoming signal analysis available as an option it includes CRC status Line standard Frame Rate Error rate Note RollCall TM enabled for remote system control monitoring ...

Page 5: ...e time 20 80 Fall time 20 80 Difference 270ps 270ps 100ps Return loss 15dB INDICATOR LEDS Not available to the Operator Standard Power Power supplies valid Fault Board fault Enhanced Monitoring Option CPU Valid CPU activity PLL Lock Output locked to input standard CRC Error Data error Line Indicates line standard Frame Indicates frame rate Prog Int Indicates progressive or interlaced frames RollCa...

Page 6: ...on one IN eight OUT the middle BNC not being used A dual channel version of the DA card is also available order number SHD_SDA2x S2 which contains two separate four output amplifiers A dual channel DA also has a 10 BNC rear interface card two lots of 1 IN four OUT The only difference between the rear interface cards for the two types of DA is in the backpanel labelling Mechanically these two diffe...

Page 7: ...nt and the n is the connection number for that particular rear interface Standard Input Electrical HD SDI Used On SHDSDA1S S1 SHDSDA1E S1 The high definition serial digital electrical input is connected to a 75Ω BNC connector The connector is shown opposite and is labelled H1 on the rear panel Standard Outputs Electrical HD SDI Used On SHDSDA1S S1 SHDSDA1E S1 The high definition serial digital ele...

Page 8: ...sure a range of monitoring information is available via RollCall External Monitoring Description General alarm Input power fault or overcurrent trip or system failure Supply voltage levels Actual voltage levels Board temperature Actual board temperature CRC Status Line Standard Frame Rate Bit error rate Error rate over defined time period ...

Page 9: ...alue in this field is a guide to the strength of equalisation that is being applied to the input signal for longer cable runs The lower the value the less equalisation is being employed It is intended as a guide for troubleshooting the system It should be noted that when an equalisation of 100 is shown it doesn t necessarily mean that the maximum input cable length has been reached As soon as CRC ...

Page 10: ...Record Date Version No Issue No Change Comments 16 06 01 1 1 First draft document Issued 051001 1 2 Edited current feature list Only states features that are present in current release A1 0 000 New issue released 030402 1 3 New monitoring features added New issue released ...

Reviews: