3-14
Performer-HD Instruction Manual
Section 3 — Operation and Maintenance
To combine preset and take into a single command:
<CR>3C08D030501A
To query Performer-HD:
<CR>3C03Q01
If all levels were connected to source 3 and protected, the query re-
sponse would be:
<CR>3C08SP000301
(Where level 00 indicates all levels)
If levels 1 and 3 were connected to source 10 and level 2 to source 1 and
unprotected, the response would be:
<CR>3C10SC000A01SC020101
The response contains two
S
commands. In the first, level 00 indicates
all levels are connected to source 10 (0A), but the second indicates that
level 2 is in fact connected to source 1 (takes precedence over the first
response). This technique reduces the number of characters in the re-
sponse message by using the all levels value for the source connected
to the greatest number of levels followed by a specific message regard-
ing sources connected to other levels.
If level 1 were connected to source 3, level 2 to 8, and level 3 not con-
nected, the response would be:
<CR>3C18SP000301SP020801SP030001
The first
S
command specifies level 00, not level 01. The first
S
com-
mand in a status response is always for level 00 (all levels).
Summary of Contents for PERFORMER-HD
Page 5: ...Performer HD Instruction Manual v Contents Glossary Index ...
Page 6: ...vi Performer HD Instruction Manual Contents ...
Page 8: ...viii Performer HD Instruction Manual Preface ...
Page 32: ...2 14 Performer HD Instruction Manual Section 2 Installation ...
Page 54: ...3 22 Performer HD Instruction Manual Section 3 Operation and Maintenance ...
Page 58: ...Glossary 4 Performer HD Instruction Manual VCO Voltage Control Oscillator ...