Performer-HD Instruction Manual
3-13
Serial Protocol Descriptions
indicates the source settings set by
<Src Hi>
and
<Src Lo>
.
indicates the destination setting set by
<Dest Hi>
and
<Dest Lo>
.
Examples
In the following examples the Performer-HD address is set to 3C hex.
To preset level 3 of source 5 to destination 1, send these characters:
<CR>3C07D030501
In the example, 3C= <Adr>, 07=<Len>, and D030501= <Data>.
To take the preset values to the switcher output, send these characters:
<CR>3C01A
or, use the T command:
<CR>3C03T01
Table 3-7. Source Settings
Src Hi
Src Lo
Result
0
0
No Source
0
1
Source selection 1
0
2
Source selection 2
0
3
Source selection 3
0
4
Source selection 4
0
5
Source selection 5
0
6
Source selection 6
0
7
Source selection 7
0
8
Source selection 8
0
9
Source selection 9
0
A
Source selection 10
Table 3-8. Destination Setting
Dest Hi
Dest Lo
Result
0
1
Destination 1 (Performer -HD has only 1 destination)