71
IQH4B
User Manual
Field Name
Field Name
Description
Valid Field Values
Usage Description
TEMP_
n
_NAME=
Name of temp sensor TEXT
Function name such
as Temperature In,
Temperature Out,
Internal Temperature,
PSU 1 Temperature,
etc.
These are set by the
product and are not
user-definable.
TEMP_
n
_STATE=
Temperature status
OK - Temp is within
operating range.
WARN: Low - Temp
below normal
operating range, but
not critical.
WARN: High - Temp
above normal
operating range, but
not critical.
FAIL: Low - Temp
below normal
operating range,
Critical.
FAIL: High - Temp
above normal
operating range,
Critical.
FAIL:Not Available -
Sensor not detected.
FAIL:Sensor Fault -
Sensor malfunction.
Disabled -
Temperature
detection has been
manually disabled.
Each product must
specify its own
operating ranges and
safety thresholds,
however suggestion is
that
WARN
thresholds
exist 5 degrees C away
from defined product
FAIL
thresholds, e.g:
product specification
is 0-40 Degrees C, so
WARN
will be <= 5
and >=35.
TEMP_
n
_CELSIUS=
Temperature in °C
Number
Temperature in
Celsius.
Value will be blank if
temperature sensor is
not enabled.