IQDMX01/03/11/13
B5
IQDMX01OPS 05/04/07
www.snellwilcox.com
Version 1 Issue 12
B5.66
◀
◀
◀
◀
Information Window
Chroma_B/W
Information Window
Input Status
EDH & ANC Status
Audio Input Status
Reset Errors
The type if information that appears in the
Information Window may be chosen with this item.
◀
◀
◀
◀
Reset Errors
Selecting this function will reset the EDH error
count and the timer shown in the information
window, to zero.
◀
◀
◀
◀
Default Output
If the input signal fails or is of poor quality this
function will determine what the output signal will
become under such conditions.
Video
Freeze
Pattern
Black
EBU Colour Bars
100% Colour Bars
Ramp
Multiburst
Pulse & Bar
Default Output
◀
◀
◀
◀
Pattern
If Pattern is chosen in the
Default Output
menu
the output will become the pattern chosen from the
list.
◀
◀
◀
◀
Unit
This provides various items of information about
the unit.
Unit
Software Version
Serial No
Preset Unit
Restart
Build No
◀
Software Version
This item reveals a display showing the version of
the software fitted in the module.
Software Version
Software Version
x.x.x
OK
Select OK to return to the Unit Menu.
◀
◀
◀
◀
Serial No
This item reveals a display showing the serial
number of the module.
Serial No
Serial No
xxxxxxx
OK
Select OK to return to the Unit Menu.
◀
Preset Unit
Selecting this item sets all adjustment functions
that include a preset facility, to their preset values.
Note that this is a momentary action.
◀
Restart
This will reboot the unit simulating a power-down
power-up cycle restoring power-up settings.
◀
Build No
This will indicate the factory build number. This
number defines all parameters of the unit (software
versions, build level etc.) for identification
purposes.
Build No
Build No
xxxxxxx
OK
Select OK to return to the Unit Menu.