11
Operation
Indicators
During setup and operation, system functionality can be monitored on the HPE-300/HPE-
300-2AC front panel. A group of LED indicators provide operational and diagnostic
information as well as hardware status.
CAMERA STANDBY/ON indicator
This indicator lights GREEN (default) when the high voltage (300 VDC) is present and
camera power is switched on. The indicator lights YELLOW when AC power is present and
the camera is switched to low voltage/standby mode.
CAMERA CONNECTION
This indicator lights GREEN (default) when a valid camera connection is detected. It is off
when there is no camera connection.
☞
Note
☞
Note
This LED is also used as an indicator for the internal FPGA code revision. At power up, this
LED flashes an appropriate number of times equal to the revision number of the code
installed in the unit's FPGA.
3
5
6
4
2
1
HPE-300-2AC model only
1
2