92
Concerto — Instruction Manual
Section 2 — Installation
Ethernet Communications
Ethernet is used for communication between the Concerto and either an
Encore or SMS 7000 Control System frame. Communications can be estab-
lished using either
E-NET 1
(to communicate with the Controller in slot 1) or
E-NET 2
(to communicator with the Controller in slot 2). One connection can
be used as a primary connection and the other can be used as a redundant
connection. See
.
Figure 50. Network Connection between Concerto and Control Frame
References
Concerto requires a Video Reference. Most composite analog video sync
signals will work with the exception of 4 Volt and 2 Volt discreet sync sig-
nals. Color Black is recommended. To allow time stamped deterministic
switching, the Video Reference must contain an embedded Vertical Interval
Time Code (VITC) signal.
The AES sync reference loop-thru input provides a 48 kHz formatted signal
for re-synchronization to frame and block boundaries. The signal is
required for the Analog Audio and the Digital Audio (AES) modules to
function properly. Lack of this signal will cause the router to add or drop
samples.
The Concerto matrix supports multiple independent switch point reference
signals. Multiple reference signals support synchronously switching
groups of sources with different repetition rates (PAL/NTSC) or offset
timing (delay from studios vs. direct feeds).
Reference signals can be routed via loop-thru daisy-chains. The signal orig-
inates at a generator. It can then either be directly fed into the Concerto
Concerto
EXT COM
2
EXT COM
1
E-NET
2
E-NET
1
AES REF
VID-REF 2
VID-REF 1
25
21
17
13
9
5
1
22
18
14
10
6
2
26
23
19
15
11
7
3
28
27
30
29
31
32
24
20
16
12
8
4
31
27
23
19
15
11
7
28
24
20
16
12
8
32
29
25
21
17
13
9
30
26
22
18
14
10
5
6
3
4
1
2
INPUTS
OUTPUTS
EXP
IN
EXP
OUT
AUDIO/DATA
TDM
MON IN
MON OUT
1
2
1
2
25
21
17
13
9
5
1
22
18
14
10
6
2
26
23
19
15
11
7
3
28
27
30
29
31
32
24
20
16
12
8
4
31
27
23
19
15
11
7
28
24
20
16
12
8
32
29
25
21
17
13
9
30
26
22
18
14
10
5
6
3
4
1
2
INPUTS
OUTPUTS
EXP
IN
EXP
OUT
AUDIO/DATA
TDM
MON IN
MON OUT
1
2
1
2
A 29 B
A 25 B
A 30 B
A 26 B
A 31 B
A 27 B
A 32 B
A 28 B
A 23 B
A 21 B
A 24 B
A 22 B
A 19 B
A 17 B
A 20 B
A 18 B
A 15 B
A 13 B
A 16 B
A 14 B
A 11 B
A 9 B
A 12 B
A 10 B
A 7 B
A 3 B
A 8 B
A 4 B
A 29 B
A 25 B
A 30 B
A 26 B
A 31 B
A 32 B
A 29 B
A 30 B
A 27 B
A 28 B
A 25 B
A 26 B
A 23 B
A 24 B
A 21 B
A 22 B
A 19 B
A 20 B
A 17 B
A 18 B
A 15 B
A 16 B
A 13 B
A 14 B
A 11 B
A 12 B
A 7 B
A 8 B
A 5 B
A 6 B
A 3 B
A 3 B
A 1 B
A 2 B
A 9 B
A 10 B
A B
A B
EXP. OUT
EXP. IN
1
1
2
2
MON. OUT
MON. IN
OUTPUTS
INPUTS
400W; 11.1A
36-60V
+
-
AC PWR 1
AC PWR 2
500W; 5A
50/60Hz
100-240V
ALARM
1 2 9 10
3 4 11 12
5 6 13 14
7 8 15 16
21 22 25 26
23 24 27 28
29 30 31 32 3 4 7 8
1 2 5 6
11 12 15 16
9 10 13 14
19 20 27 28
17 18 25 26
23 24
17 18
21 22
19 20
31 32
29 30
IN OUT
EXP. OUT
EXP. IN
1
1
2
2
OUTPUTS
INPUTS
IN
OUT
MONITOR
AES BALANCED BACKPLANE
+
G +
G
+
G +
G
+
G +
G
AA BACKPLANE
8138_00_18r1
Managed
Ethernet Switch
To Control Frame
Summary of Contents for Concerto
Page 1: ...Concerto ROUTING MATRIX Instruction Manual Software Version 1 7 6 1 071813811 OCTOBER 2009 ...
Page 3: ...Concerto ROUTING MATRIX Instruction Manual Software Version 1 7 6 1 071813811 OCTOBER 2009 ...
Page 8: ...8 Concerto Instruction Manual Contents Glossary 159 Index 169 ...
Page 10: ...10 Concerto Instruction Manual Preface ...
Page 26: ...26 Concerto Instruction Manual Regulatory Notices ...
Page 102: ...102 Concerto Instruction Manual Section 2 Installation ...