out. Be especially careful to check that the
spray pipes are not blocked.
·Wipe the level guard (see ill. 17).
·The drip channel should also be washed
clean and dried. It is important that this
is done to avoid the channel becoming
blocked.
·Wipe the door seals.
·Wipe the inside of the machine with a
damp cloth. The outside of the machine
should not be washed with high pressure
water.
·The top should be wiped off as required
or at least once a month.
Replacement of fittings
Replace all fittings.
Ensure the handle on the sieve cover is
pressed in (ill. 17).
It is important that the spray pipes are
secured properly. If this is a problem it
could be that there are granules between
the spray pipe and the rubber seal. Take
out the spray pipe, remove any granules
and try again. Never use force to fit the
spray pipes
NB! If the overflow sieve is not put back then
the granules will run down the drain.
During longer stoppages
·Ensure that the wash tank is completely
empty after cleaning. Any water remaining
in the bottom should be removed with a
sponge or something similar.
·Leave the doors slightly open so that the
air can circulate in the machine.
·The granules should be stored in the gran-
ule collector standing in the machine.
·After a longer stoppage; check the opera-
tion of the machine according to the serv-
ice manual, possibly with the assistance of
a service engineer.
·For stoppages of more than three months
see the routines for shutting down in the
service manual.
17