SERVO MOTOR BLOCKED is scrolling across the bottom of the burner control panel display.
Check the following:
•
With the burner STANDBY/ON switch set to the STANDBY position, remove the pellet feed tube from the
burner and open the combustion chamber door.
•
Is the brazier blocked with ash/clinker? If yes, remove the blockage and close the combustion chamber door.
Reset the STANDBY/ON switch to ON and wait for the cleaning process to be completed.
If, after checking the above, there is still a problem then contact your Installer for assistance.
STEP 7
PROBE FAULT is scrolling across the bottom of the burner control panel display.
Check the following:
•
Are the three plugs correctly fitted to the left side of the burner?
•
Press the RESET button on burner control panel to clear error message.
If, after checking the above, there is still a problem then contact your Installer for assistance.
STEP 8
AIR PRESSURE ERROR is scrolling across the bottom of the burner control panel display.
Check the following:
•
Press the RESET button on the burner control panel to clear error message.
If there is still a problem then contact your Installer for assistance.
WARNING
Do not under any circumstances enter a bulk pellet store or pellet hopper that has been in operation as there may be a build-up of fumes within
the enclosure if the boiler has malfunctioned.