Note:
Condensing Combi boilers are only for use with kerosene.
Model
Burner
Heat Output
Net
Nozzle
Oil
Smoke
Burner
Fuel flow Flue gas
C0
2
type
eff *
press.
No.
head
rate
temp.
(kW)
(Btu/h)
%
(bar)
(kg/h)
(˚C)
(%)
26
Riello RDB1
26.0
88 700
101.0
0.75/80˚EH 8.0
0 - 1
T2
2.16
78
12.0
36
Riello RDB2.2 36.0 123 000 101.5
1.00/80˚EH 9.1
0 - 1
T5
3.01
78
12.0
Notes:
1 The data given above is approximate only and is based on the boiler being used with a low level balanced flue.
2 The above settings may have to be adjusted on site for the correct operation of the burner.
3
Gas Oil is not suitable for use with a Condensing Combi boiler.
4 * Net thermal efficiency.
5 The net flue gas temperatures given above are ± 10%.
6 When commissioning the air damper
must
be adjusted to obtain the correct CO
2
level.
7 The combustion door test point may be used for CO
2
and smoke readings only. Do not use this test point for temperature or
efficiency readings.
Flue gas analysis
To allow the boiler to be commissioned and serviced, the boiler is supplied with a combustion test point on the front cleaning door.
When this test point is used please note the following:
1 . The test point is for CO
2
and smoke readings only.
2. The temperature and efficiency readings must be taken from the flue terminal.
Outdoor Condensing Combi Boilers using Class C2 kerosene
\
4.6
Outdoor Combi 90 V3, Combi Max and Condensing Combi
11
4 – BOILER TECHNICAL INFORMATION