background image

 

C1GR, C1GR US, C2GR, C2GR US, CC26R, CC26R US 

 

 

Operating manual Part No. 34960 

 

Page 8 

www.grantinstruments.com

 

4. 

 Maintenance and Service 

 

4.1 

General 

 

No routine maintenance is required except for cleaning the condenser fins and enclosure (see 
section 3.2). There are no user serviceable parts inside the unit. If the unit is visibly damaged or 
does not operate correctly, please contact our service department in the UK (see section 5), or 
your local distributor (outside the UK) to arrange repair.

 

 
4.2 

Cleaning 

 

4.2.1 

General

 

 

The enclosure can be cleaned with a lightly damped soft cloth after disconnection from the supply.  
Do not use strong and/or aggressive solvents. The immersed coil assembly can be cleaned with 
soapy water.

 

Before using any other decontamination or cleaning method, except that recommended above, 
check with our Service Department, or in other countries with our distributor, that the proposed 
method will not damage or impair the safety of the equipment. 

 

4.2.2 

Condenser cleaning 

 

Cooling power will be reduced if the refrigeration condenser fins become blocked with dust and/or 
foreign material pulled in by the cooling fan. The equipment should be internally cleaned by a 
suitable qualified electrician and/or Grant appointed representative on a regular basis to prevent 
the build-up of foreign material within the equipment. 
 

4.3 

Routine safety tests 

 

If routine tests are to be made, we recommend a test of the integrity of the protective earth 
conductor and an insulation test at 500 V DC. Routine flash tests are not recommended for any 
electrical equipment, because repeated high voltage tests degrade insulation materials.

 

 

4.4  

Replacement of fuses 

 

Disconnect the mains plug from the supply.  Remove the IEC power connector from the rear of the 
equipment. Using a suitable blunt tool, release the fuse drawer retaining clip and slide out the fuse 
drawer. Check and replace with the correct fuse type, as previously fitted, or if necessary as 
detailed below: 
 
 Size: 1.25 x 0.25-inch (31.75x6.35mm), ceramic (high breaking capacity), qu

ick acting type ‘F’ 

 
  

Model C1GR:   

220-240V: 

5AF 

 

115-120V: 

10AF 

  

Model C2GR:   

220-240V: 

10AF 

 

115-120V: 

10AF 

  

Model CC26R:   

220-240V: 

10AF 

 

115-120V: 

10AF 

 

After inserting the replacement fuses into the fuse holders, slide the drawer back into the aperture 
provided in the AC-inlet and replace the IEC power connector. 

 

4.5 

Disposal 

 

This unit contains refrigerant gas which must NOT be discharged into the atmosphere.  At the end 
of the unit’s working life, either have the gas removed safely by using refrigerant recovery 
equipment or return the unit to Grant Instruments for disposal. 
 
 

 

 

 

Summary of Contents for C1GR

Page 1: ...Refrigerated immersion Coolers C1GR C2GR CC26R Operating Manual...

Page 2: ...t Instruments Cambridge Ltd Shepreth Cambridgeshire SG8 6GB UK Tel 44 0 1763 260 811 E mail support grantinstruments com Representative in the European Union Grant Instruments Europe B V Strawinskylaa...

Page 3: ...s 7 3 1 Operating condition 7 3 2 Electrical details 7 3 3 Performance and dimensions 7 4 Maintenance and service 6 4 1 General 8 4 2 Cleaning 8 4 2 1 General 8 4 2 2 Condenser cleaning 8 4 3 Routine...

Page 4: ...ect only to an ac power mains outlet with a voltage corresponding to that on the serial number label This product must be connected to an earthed ac power mains outlet Before moving disconnect from th...

Page 5: ...age trip Check that the voltage rating of the products given on the serial plate next to the power cable entry is correct for your supply Fit the mains cable appliance coupler into the IEC socket at t...

Page 6: ...cool down the liquid not to operate continuously above 40 C Immersed material the cooling coil is nickel plated copper 2 2 1 CC26R The CC26R is designed for use with the Grant OLS26 shaking water bath...

Page 7: ...ge fluctuations are not to exceed 10 of the nominal supply voltage C1GR Mains supply 220 240V 50Hz 115 127V 60Hz Power consumption 0 9 A 3 0A C2GR Mains supply 220 240V 50Hz 115 127V 60 Hz Power consu...

Page 8: ...ed electrician and or Grant appointed representative on a regular basis to prevent the build up of foreign material within the equipment 4 3 Routine safety tests If routine tests are to be made we rec...

Page 9: ...for THREE YEARS against faulty materials or workmanship Service repairs outside of the guarantee period by Grant Instruments carry a further one year guarantee 6 Service For service return for repair...

Page 10: ...Agency this reference number is WEE GA0048TZ For other countries please contact your equipment supplier For General WEEE information please visit www b2bcompliance org uk 7 2 RoHS Directive All the pr...

Page 11: ...C1GR C1GR US C2GR C2GR US CC26R CC26R US Operating manual Part No 34960 Page 11 www grantinstruments com Notes...

Page 12: ...ents Cambridge Ltd Representative in the European Union Shepreth Grant Instruments Europe B V Cambridgeshire Strawinskylaan 411 SG8 6GB WTC Tower A 4th Floor UK 1077 XX AMSTERDAM THE NETHERLANDS Tel 4...

Reviews: