Section 3: Installation
Page 9
3.7.2 AERONA³ HPID10R32 HEAT PUMP
Refer to Figure 3-10 for the connection arrangement between the
external volumiser and an HPID10R32 heat pump.
For details of the pipe and fittings required to make the connection
between the heat pump and external volumiser refer to Figure
3-11.
Return from system
Flow to system
Figure 3-10:
External volumiser connection to HPID10R32 heat
pump
1
2
3
4
5
6
7
8
6
9
Figure 3-11:
External volumiser connection to HPID10R32 heat
pump (exploded image)
Table 3-3:
Key to Figure 3-11
Item
Description
Source
1
External volumiser
N/A
2
Volumiser inlet connection -
28mm compression
Supplied on
Volumiser
3
Copper pipe 28mm - length to suit
Supplied by installer
4
Elbow - 28mm compression
Supplied by installer
5
Copper pipe 28mm - length to suit
Supplied by installer
6
Flexible hose -
1” BSP x 28mm c/w washer
Supplied with heat
pump
7
Heat pump flow connection - 1” BSP
N/A
8
Volumiser outlet connection -
28mm compression
Supplied on
Volumiser
9
Heat pump return connection -
1” BSP
N/A