Section 1: Introduction

Page 4

1.1 GENERAL

A ‘volumiser’ is simply a vessel used to increase the volume of the 

heating system connected to the heat pump. It has one inlet and 

one outlet for connection to the heat pump and heating system.
The Grant External volumiser can be used in the following 

situations:

a)  Where there is insufficient water volume in the heating 

system connected to the heat pump.

b)  Where there is no available space inside the property to 

accommodate a volumiser/low loss header, such as the 

Grant combined volumiser/low loss header.

c)  When a plate heat exchanger is used to provide hydraulic 

separation between the heat pump and the heat emitter 

circuits.

The Grant External 30 litre volumiser is an insulated rectangular 

tank fitted with a single 3kW electric immersion heater and is 

designed for use with the Grant Aerona³ air source heat pumps. 

This is housed within a weatherproof external casing with a 

removable cover at one end to access the electrical connections 

and immersion heater.

It is designed to be located behind the Aerona³ heat pumps, on 

the same anti-vibration mounts (Grant product code: HPIDFOOT/

KIT2) as the heat pump, using the mounting brackets provided 

with the volumiser. See Figure 1-1.

1 INTRODUCTION

Figure 1-1: 

Grant External Volumiser behind Aerona³ heat pumps

HPID13R32 & HPID17R32

HPID10R32

HPID6R32

! NOTE !

This volumiser is designed to be installed in the flow from 

the heat pump.

The volumiser has two pipe connections located on the upper 

surface of the unit. Refer to Figure 2-1. These are 28mm 

compression connections. Refer to Section 3.6 for further details 

on the connections to the external volumiser.
The flexible hoses supplied with the Grant Aerona³ will be used to 

connect the External Volumiser to the heat pump. 
The 3kW electric immersion element is supplied, factory fitted 

and located inside a removable panel at the right-hand side of the 

volumiser (viewed from the front). 
It is intended to provide a backup heat source controlled by the 

Grant Aerona air source heat pump to which it is connected. Refer 

to Section 4 – Electrical.
The shell of the volumiser is a mild steel welded construction, 

insulated with mineral wool. This is enclosed within an outer 

galvanised steel casing with a powder coated paint finish to match 

the casing of the heat pump.

The volumiser is fitted with a ½” drain cock, located to the left of 

the immersion heater, to allow the volumiser to be drained down if 

required.

! WARNING !

The immersion heater must NOT be used unless it is fully 

immersed in water. Always ensure that the electrical supply 

to the volumiser/immersion heater is isolated BEFORE 

draining down the volumiser.

Always ensure that volumiser is fully refilled with water 

BEFORE switching the electrical supply back on

1.2 

PRODUCT CONTENTS

The Grant External Volumiser is supplied as a pack, in a box, 

containing the following items:
• 

1 x External Volumiser c/w immersion heater

• 

2 x Mounting Brackets

• 

1 x Cable gland M20mm

• 

1 x Cable gland M16mm

• 

1 x Installation instructions

1.3 

PIPE FITTINGS FOR HPID6R32 ONLY

As the INLET on the top of the external volumiser is higher than 

the flow connection on the back of the HPID6R32 heat pump, an 

elbow with an integral manual vent must be fitted to the volumiser 

inlet to allow the volumiser to be vented of any air. Refer to Figure 

3-8.
The necessary 22mm compression elbow with integral manual 

air vent is supplied with the heat pump for this connection 

arrangement.

Two 28mm x 22mm compression reducing sets are also supplied 

with the heat pump. These to allow 22mm pipe to be connected to 

the 28mm inlet and outlet connections on the external volumiser. 

Refer to Figure 3-9.

Summary of Contents for Aerona3 HPID10R32

Page 1: ...UK DOC 0183 Rev 1 0 November 2022 Grant External Volumiser Installation Instructions...

Page 2: ...e Grant External Volumiser SPECIAL TEXT FORMATS The following special text formats are used in these instructions for the purposes listed below WARNING Warning of possible human injury as a consequenc...

Page 3: ...5 Unpacking 6 3 6 Installation procedure 6 3 7 System connections 7 4 ELECTRICAL 11 4 1 General 11 4 2 Electrical connections 11 4 3 Immersion heater 12 5 OPERATION 14 5 1 General 14 5 2 Aerona heat p...

Page 4: ...External Volumiser to the heat pump The 3kW electric immersion element is supplied factory fitted and located inside a removable panel at the right hand side of the volumiser viewed from the front It...

Page 5: ...coated Insulation Mineral wool Immersion Heater Make Cotherm TSR Output kW 3 Electrical supply 230V 50Hz 1ph 2 1 TECHNICAL SPECIFICATION 2 TECHNICAL DATA 2 2 DIMENSIONS Figure 2 1 Grant External Volu...

Page 6: ...the heat pump and the front face of the external volumiser If the rear face of the volumiser is 50mm from the wall this will leave a distance of approximately 400mm between the wall and the back of t...

Page 7: ...re the heat pump feet to the AV mounts The gap between the rear of the heat pump and the front of the External Volumiser should be approximately 100mm Refer to Figure 3 6 If not then slacken the four...

Page 8: ...ize of heat pump the volumiser is connected to Refer to the following details for the model of heat pump being fitted 3 7 1 AERONA HPID6R32 HEAT PUMP As the INLET on the top of the external volumiser...

Page 9: ...3 4 5 6 7 8 6 9 Figure 3 11 External volumiser connection to HPID10R32 heat pump exploded image Table 3 3 Key to Figure 3 11 Item Description Source 1 External volumiser N A 2 Volumiser inlet connecti...

Page 10: ...with heat pump 8 Heat pump flow connection 1 BSP N A 9 Volumiser outlet connection 28mm compression Supplied on Volumiser 10 Heat pump return connection 1 BSP N A Figure 3 13 External volumiser conne...

Page 11: ...he supplementary immersion heater uses a dedicated power supply from a correctly sized circuit breaker in the consumer unit The final supply connection must be made from a weatherproof lockable isolat...

Page 12: ...for external volumiser connection diagram 4 3 IMMERSION HEATER The Grant External Volumiser is supplied factory fitted with a pre wired 3kW Cotherm Type TSR immersion heater WARNING The immersion hea...

Page 13: ...level or slightly above the surface of the housing To reset the over temperature cut out Isolate the volumiser immersion element from the mains electrical supply Wait for the temperature in the volum...

Page 14: ...tting menus via the heat pump remote controller refer to Aerona installation instructions Section 9 3 Set the parameters as detailed in the table below Table 5 1 Aerona heat pump parameter settings fo...

Page 15: ...e Industrial Estate Swindon SN5 8YG Telephone 44 0 1380 736920 Fax 44 0 1380 736991 Email info grantuk com Website www grantuk com Product 30Ltr EXTERNAL VOLUMISER C W 3KW BACKUP HEATER Model HPIDVOL3...

Page 16: ...artment on 44 0 1380 736920 who will arrange for a competent service engineer to rectify the fault Remember before you contact Grant Engineering UK Limited Ensure the External Volumiser has been insta...

Page 17: ...Limited must be informed of the new owner s details The Company will endeavour to provide prompt service in the unlikely event of a problem occurring but cannot be held responsible for any consequence...

Page 18: ...Page 18 Notes NOTES...

Page 19: ...Notes Page 19 NOTES...

Page 20: ...GRANT ENGINEERING UK LIMITED Frankland Road Blagrove Industrial Estate Swindon SN5 8YG Tel 44 0 1380 736920 Fax 44 0 1380 736991 Email info grantuk com www grantuk com...

Reviews: