Position no. 

Description 

Order number 

Quantity 

42 

Capacitor 

61099049/42 

43 

Screw M5x12   

61099049/43 

44 

Nut M8   

61099049/44 

45 

One-way valve 

61099049/45 

46 

Pressure line Ø 6,5   

61099049/46 

47 

Screw M8x25   

61099049/47 

48 

Pressure line Ø 10   

61099049/48 

49 

Nut M10   

61099049/49 

50 

Spring Ø 10    

61099049/50 

51 

Washer Ø 10    

61099049/51 

52 

Wheel    

61099049/52 

53 

Wheel shaft    

61099049/53 

54 

Drain valve   

61099049/59 

55 

M8x30 bolt   

61099049/54 

56 

Rubber foot    

61099049/55 

57 

Nut M8   

61099049/56 

58 

Spindle Rp1/2   

61099049/57 

59 

Pressure vessel 

61099049/58 

60 

Power cable    

61099049/60 

61 

Nut Rp1/2    

61099049/61 

62 

Quick couplings   

61099049/62 

63 

Regulating valve   

61099049/63 

64 

Safety valve    

61099049/64 

65 

Pressure gauge    

61099049/65 

66 

Pressure switch    

61099049/66 

67 

Supply line    

61099049/67 

68 

Sealing plug 

61099049/68 

 

 

11.

 

Scope of delivery 

No. 

Description 

Number 

Compressor 

Air filter 

air intake pipe 

Rubber seal ring 

Operating instructions 

 

 

 

Summary of Contents for 61099049

Page 1: ...ctions Pump 61099049 These operating instructions must be read thoroughly before use and followed These Operating Instructions must be retained for future reference Translation of the original operati...

Page 2: ...sor 9 4 3 Operating a pressure tank 10 4 4 Operation at cold temperatures 10 4 5 Operating the equipment 10 4 6 Switching off the compressor 11 5 Maintenance and care 11 5 1 General maintenance instru...

Page 3: ...the item numbers in the tables Instructions for which the order must be followed are numbered 1 2 3 Lists are marked with bullet points Symbol labels on the device with their meaning Wear hearing pro...

Page 4: ...operation residual hazards and risks become apparent which are not described in this manual the operator is obliged to report this to the manufacturer Do not change the setting of the safety valve Be...

Page 5: ...d against the penetration of medium sized foreign bodies from 12 5 mm It is not protected against the penetration of liquids Therefore the equipment must not be used in damp or wet rooms or outdoors i...

Page 6: ...f using the switch Fig 2 and then disconnected from the mains by pulling the mains plug The compressor can only be prepared for operation by people with sufficient technical expertise All other operat...

Page 7: ...nstructions for correcting malfunctions in Chapter 8 of this manual Failure to observe the safety instructions can result in damage to property and personal injury Before the compressor is restarted w...

Page 8: ...ed is clean dry and well ventilated Make sure that the electrical voltage is constant and does not deviate from the prescribed voltage by more than 4 Make sure that the oil level is within the red ind...

Page 9: ...a good reason and the permissible operating pressure of the compressor should never be exceeded If the permissible operating pressure is exceeded and safety switches and valves are manipulated this c...

Page 10: ...gularly for damage e g rust If you discover any damage contact your specialist dealer immediately 4 4 Operation at cold temperatures At low temperatures the oil in the crankcase becomes thick and visc...

Page 11: ...tch off the compressor press down the on off switch see Fig 2 The unit must never be switched off by pulling out the mains plug Pulling out the mains plug without first pressing down the button on the...

Page 12: ...ional safety of the unit for as long as possible After the first 10 operating hours the crankcase should be cleaned and the oil renewed The oil level Fig 4 no 20 should be checked every 20 operating h...

Page 13: ...at the bottom of the boiler Drain the condensate at least once a week To do this open the drain screw at the bottom of the boiler Fig 1 no 7 until there is no more water in the air coming out The con...

Page 14: ...he unit using the transport bracket provided Always store the compressor in a dry and frost proof room If the compressor is not used for a longer period of time switch it off when it is completely dis...

Page 15: ...g parts worn out 1 Check and re fasten 2 Check and remove foreign body Insufficient pressure build up or reduced ventilation 1 Motor running too slowly 2 Air filter clogged 3 Safety valve leaking 4 Ve...

Page 16: ...Compressor Operating Instructions 61099049 16 9 Component drawing with installation position Figure 4...

Page 17: ...be 61099049 16 1 17 O Circlip 18 3x 2 65 O 61099049 17 2 18 Screw M5x16 61099049 18 4 19 Crankcase cover 61099049 19 1 20 Oil level regulator 61099049 20 1 21 M6x10 bolt 61099049 21 1 22 O Circlip 5 6...

Page 18: ...shaft 61099049 53 2 54 Drain valve 61099049 59 1 55 M8x30 bolt 61099049 54 1 56 Rubber foot 61099049 55 2 57 Nut M8 61099049 56 2 58 Spindle Rp1 2 61099049 57 2 59 Pressure vessel 61099049 58 1 60 Pow...

Page 19: ...ical equipment EC protection objectives were met according to Annex I No 1 5 1 of the Machinery Directive 2006 42 EC The machine also complies with the 2014 29 EU regulations on simple pressure tanks...

Page 20: ...700 Postal and shipping address Wilhelm Fricke SE Zum Kreuzkamp 7 DE 27404 Heeslingen 15 Legal Notice Translation of the original operating instructions for a Compressor Model 61099049 Manufacturer W...

Reviews: