O
perating Instructions for Digital Fence Tester
580580479
6
5
Operation
An electric shock can lead to death or serious injury! The
equipment may only be used by instructed persons who observe
all safety instructions.
Electric shock due to insufficient insulation. Always check the
equipment for damage and proper functioning before each use. If
you discover any damage, stop using the equipment.
Do not use the equipment if the equipment or your hands are
damp or wet!
Do not use the equipment if the battery compartment or housing
is open.
Electric shock by touching live parts. Do not touch live parts.
Protect adjacent live parts by covering them or switching them
off.
Before each measurement, test the function of the equipment at
a known voltage source.
5.1
Initial start up
Remove the battery cover.
Insert the battery (1 x 9 V AAA battery) into the battery compartment with the correct
polarity.
Close the battery compartment with the cover removed.
Before each voltage test, check that the equipment functions reliably with a known
voltage source.