Granit 50700006 User Manual Download Page 5

                      

 

Instruction 

Manual

 

 

50700006 

 

5    LCD screen 

 

Pos.No.  Description 

Pos.No.  Description 

Primary display panel: display the 
measured temperature 

Battery under-voltage indication 

Functional indication: display Max 
PRb (K type probe), E (emissivity)  
(adjust the instrument’s 
emissivity) 

Temperature measurement 
indication 

Secondary display panel 

Data hold 

Fahrenheit unit 

Laser enabling indication 

Celsius unit 

 

 

 

 

 

Summary of Contents for 50700006

Page 1: ...ARED THERMOMETER 50700006 These operating instructions must be read thoroughly before use and followed carefully Please retain these operating instructions for future reference Translation of the orig...

Page 2: ...ions 3 3 Important notices 3 4 Physical appearance 4 5 LCD screen 5 6 Mesurement method 6 7 Proportion between the distance from probe to object and the diameter of the object to be measured D S 10 8...

Page 3: ...nstrument Don t cleanse the temperature measuring instrument with any solvent Safety symbols Important notices against hazards Compliant with European CE safety directive This instrument complies with...

Page 4: ...ption Pos No Description 1 Alarm indicator 7 Laser indicator 2 LCD screen 8 UV 3 Laser control key numeric adjustment key 9 K type 4 Mode key 10 Measurement trigger 5 Backlight UV control key numeric...

Page 5: ...display the measured temperature 6 Battery under voltage indication 2 Functional indication display Max PRb K type probe E emissivity adjust the instrument s emissivity 7 Temperature measurement indic...

Page 6: ...ng press on the key will mean rapid increase or decrease in the set value The default alarm value for this instrument is 800 C 2 Set low alarm value for the instrument Press trigger mode key to set th...

Page 7: ...r the instrument switch Mode key to the low limit set for an alarm At this moment the instrument s functional indication area shows and secondary display panel the emissivity for an alarm Press key to...

Page 8: ...tion system fluorescent agent will with the refrigerant in the air conditioning system in circulation when the air conditioning system has a leak fluorescent agent will left leakage Fluorescence leaka...

Page 9: ...ed indicator of the instrumentwill be on to sound an alarm Otherwise the green indicator will be on 8 K type Temperaturemeasurement After K type thermocouple probe is inserted into the thermocouple so...

Page 10: ...is the meter can see nothing but the object to be measured The greater the object to be measured is the farther the distance detected by the meter may be The smaller the object is the shorter the dis...

Page 11: ...to be measured at the moment of measurement The effect of emissivity on measurement result must be noticed at the time of measurement The diagram provided below is a reference table for emissivity Sur...

Page 12: ...Graphite 0 9 Silicon Carbide 0 95 Clay 0 95 Concrete 0 95 Fabric 0 95 Glass plate 0 85 Sand gravel 0 95 Gypsum 08 0 95 Ice 0 98 Limestone 0 98 Paper 0 95 plastic 0 95 Soil 0 9 0 98 Water 0 93 Wood nat...

Page 13: ...esponse time 0 5S Automatic shutdown 15 seconds Operational temperature 0 40 C Storage temperature 10 C 60 C Power 9V 6F22 batery UV Yes K type 50 C 800 C 58 F 1472 F Measurement range Non contact tem...

Page 14: ...6 The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012 The product was developed in accordance with the following standards EN 55032 2015...

Page 15: ...Warranty The warranty terms of Wilhelm Fricke SE as can be found in the sales documents and the current version of the Terms and Conditions apply In case of questions please contact the company s cus...