Grand Seiko Spring Drive 9RA5 Operating Instructions Manual Download Page 15

Lumibrite

If your watch has Lumibrite

Lumibrite is a luminous paint that absorbs light energy of the sunlight and lighting apparatus in a short

time and stores it to emit light in the dark. For example, if exposed to a light of more than 500 lux for

approximately 10 minutes, Lumibrite can emit light for 3 to 5 hours. Please note, however, Lumibrite

emits the light it stores, the luminance level of the light decreases gradually over time. The duration of

the emitted light may also differ slightly depending on such factors as the brightness of the place where

the watch is exposed to light and the distance from the light source to the watch.

 * In general, when you enter a dark place from a bright environment, your eye cannot adapt to the

change in light levels quickly. At first, you can hardly see anything, but as time passes, your vision

gradually improves. (Dark adaptation of the human eye)

 * Lumibrite is a luminous paint that is completely harmless to human beings and the natural

environment; containing no noxious materials such as radioactive substance.

Reference data on the luminance

Condition

Illumination

Sunlight

Fine weather

100,000 lux

Cloudy weather

10,000 lux

Indoor (Window-side

during daytime)

Fine weather

more than 3,000 lux

Cloudy weather

1,000 to 3,000 lux

Rainy weather

less than 1,000 lux

Lighting apparatus

(40-watt daylight

fluorescent light)

Distance to the watch: 1 m 1,000 lux
Distance to the watch: 3 m 500 lux (average room luminance)
Distance to the watch: 4 m 250 lux

26

TO PRESERVE THE QUALITY OF YOUR WATCH

Troubleshooting

Troubles

Possible Causes

Solutions

The watch stops operating. The mainspring has not been

wound.

Turn the crown to wind the mainspring

and reset the time. While you are

wearing the watch or when you take it

off, check the remaining power shown

by the power reserve indicator and

wind the mainspring if necessary.

The watch stops even

though the power reserve

indicator is not showing “0”.

The watch has been left at a

low temperature (below

0°C).

Turn the crown to wind the mainspring

and reset the time. At a temperature

below 0ºC, the watch may stop if the

power reserve indicator is showing

less than one-fifth of the power

reserve.

The watch temporarily loses/

gains time.

The watch has been left in

extremely high or low

temperatures for a long time.

Return the watch to a normal

temperature so that it works accurately

as usual, and then reset the time. The

watch has been adjusted so that it

works accurately when it is worn on

your wrist under a normal temperature

range between 5ºC and 35ºC.

The watch was brought into

close contact with a

magnetic object.

Correct this condition by moving and

keeping the watch away from the

magnetic source, and reset the time. If

this action does not correct the

condition, contact the retailer from

whom the watch was purchased.

The watch was dropped,

worn while playing active

sports, hit against hard

surfaces, or exposed to

strong vibrations.

Reset the time. If the watch does not

return to its normal accuracy after

resetting the time, contact the retailer

from whom the watch was purchased.

The date changes during

daytime.

A.m./P.m. is not correctly

set.

When you set the time, note that the

moment the date changes is midnight.

When setting the hour hand, be sure

that A.m./P.m. is correctly set.

Even though you wear the

watch every day, the power

reserve indicator does not

move up.

The watch is worn on your

wrist only for a short period of

time, or the amount of arm

movement is small.

Wear the watch for an extended period

of time. Or turn the crown to wind the

mainspring.

Right after starting the

watch, it seems that the

seconds hand moves more

quickly than usual when

setting the time.

When the watch starts

moving, it takes a little time

before the speed-regulating

unit starts operating. (This is

not a malfunction.)

It takes several seconds before the

speed-regulating unit starts operating.

To set the time correctly, wait for

approximately 30 seconds after the

seconds hand starts to move, and set

the time.

Blur in the display persists.

Small amount of water has

got inside the watch due to

deterioration of the gasket,

etc.

Consult the retailer from whom the

watch was purchased.

 * For the solution of troubles other than above, contact the retailer from whom the watch was

purchased.

27

TO PRESERVE THE QUALITY OF YOUR WATCH

English

Summary of Contents for Spring Drive 9RA5

Page 1: ...Printed in Japan BSJ9RCD A2002...

Page 2: ...ertake the service If your watch has a protective film for preventing scratches make sure to peel it off before using the watch If the watch is used with the film on it dirt sweat dust or moisture may...

Page 3: ...iverealizesmuchgreateraccuracythanconventionalmechanicalwatches Thewatch also embodies the concepts of Grand Seiko that continues the challenge of creating the best practical watch 1960 Released the f...

Page 4: ...lectronic micro engineering Then how could it be possible to achieve such a degree of accuracy That is explained on the next page 4 Spring Drive Mechanism 2 The power of the mainspring is regulated by...

Page 5: ...mechanical watches since the crystal oscillator controls it Note Accuracy of the Spring Drive Average monthly rate of 10 seconds or 15 seconds is the accuracy of a watch when it is worn on a wrist at...

Page 6: ...ed to the watch may damage your clothes or injure the hand neck or other parts of your body Please keep in mind that if a watch is taken off and placed down as it is the case back the band and the cla...

Page 7: ...m a faucet is high enough to degrade the water resistant performance of a water resistant watch for everyday life 10 CAUTIONS ON WATER RESISTANCE If water resistant level of your watch is defined as D...

Page 8: ...ith spring bars buckles or other parts b CAUTION If you notice any abnormalities contact the retailer from whom the watch was purchased or Grand Seiko international service network mentioned on CERTIF...

Page 9: ...ase water resistance Be careful not to screw the crown in by force as it may damage the slots of the crown Turn the crown from time to time P 23 Screw down crown The screw down crown features a mechan...

Page 10: ...level of the remaining power How to read the power reserve indicator P 16 When starting to use a stopped watch it is recommended that you turn the crown to wind the mainspring To wind the mainspring u...

Page 11: ...3 The seconds hand will stop moving when the crown is pulled out to the second click Do not stop the movement of the seconds hand for longer than 30 minutes If the stoppage of the seconds hand moveme...

Page 12: ...ir services after the guarantee period has expired if the functions of the watch can be restored by repair work we will undertake repair services upon request and payment Replacement parts Please keep...

Page 13: ...te without fail Others For the watch case dial plate hands glass band etc some alternative parts may be used for repair if necessary For length adjustment service of metallic band ask the retailer fro...

Page 14: ...ay result in the band being cut Take care not to damage the band with an edged tool Notes on skin irritation and allergy Skin irritation caused by a band has various reasons such as allergy to metals...

Page 15: ...erature below 0 C the watch may stop if the power reserve indicator is showing less than one fifth of the power reserve The watch temporarily loses gains time The watch has been left in extremely high...

Page 16: ...rcuit Oscillator frequency divider and spring drive control circuit C MOS IC 1 piece Jewels 38 jewels 1 The average rate is estimated in a condition when the watch is worn on your wrist within a tempe...

Reviews: