Linear Burner Inserts Automated Operation
Page 9
3.3 Construction of Burner Cavity
Burner Cavity Depth-
20” Minimum Cavity Depth Requirement for Subpanel Inner Mount 12”
Minimum Cavity Depth Requirement for Subpanel Outer Mount
Burner
Length
Support
Plate
Inner Mount
Inner Optimum
LxWxD (I.D.)
Burner
Supports
Required # of
Vent Openings
and Diameter
Inner Mount
3 feet
60” x 13”
61” x 13.5” x 20”
Brackets provided by GE
(4) / 2.5” Dia.
4 feet
72” x 13”
73” x 13.5” x 20”
Brackets provided by GE
(4) / 2.5” Dia.
5 feet
84” x 13”
86” x 13.5” x 20”
Brackets provided by GE
(6) / 2.5” Dia.
6 feet
96” x 13”
98” x 13.5” x 20”
Brackets provided by GE
(6) / 2.5” Dia.
7 feet
108” x 13”
110” x 13.5” x 20”
Brackets provided by GE
(8) / 2.5” Dia.
8 feet
120” x 13”
123” x 13.5” x 20”
Brackets provided by GE
(8) / 2.5” Dia.
9 feet
132” x 13”
135” x 13.5” x 20”
Brackets provided by GE
(10) / 2.5” Dia.
10 feet
144” x 13”
147” x 13.5” x 20”
Brackets provided by GE
(10) / 2.5” Dia.
Table 1. Required Dimensions for Burner Cavity (Inner Mount)
Burner
Length
Support
Plate
Outer
Mount
Inner Optimum
LxWxD (O.D.)
Burner
Supports
Required # of
Vent Openings
and Diameter
Inner Mount
3 feet
44” x 13”
45” x 10.5” x 13.5”
Brackets provided by GE
(2) / 2.5” Dia.
4 feet
56” x 13”
57” x 10.5” x 13.5”
Brackets provided by GE
(2) / 2.5” Dia.
5 feet
68” x 13”
70” x 10.5” x 13.5”
Brackets provided by GE
(3) / 2.5” Dia.
6 feet
80” x 13”
82” x 10.5” x 13.5”
Brackets provided by GE
(3) / 2.5” Dia.
7 feet
92” x 13”
94” x 10.5” x 13.5”
Brackets provided by GE
(4) / 2.5” Dia.
8 feet
104” x 13”
107” x 10.5” x 13.5” Brackets provided by GE
(4) / 2.5” Dia.
9 feet
116” x 13”
119” x 10.5” x 13.5” Brackets provided by GE
(5) / 2.5” Dia.
10 feet
128” x 13”
131” x 10.5” x 13.5” Brackets provided by GE
(5) / 2.5” Dia.
Table 2. Required Dimensions for Burner Cavity (Outer Mount)