background image

Page 4

Freestanding Waterfalls Installation and Operation   

Section 2.  General Description 

2.1  Product Overview

This manual provides instructions for installing and replacing  

Grand Effects

®

 Freestanding Waterfalls. 

 CAUTION

Grand Effects Freestanding Waterfalls are not serviceable and therefore 

contain no serviceable parts. In order to prevent risk of property damage 

and/or injury, no service should be attempted to the waterfall in the event 

of a malfunction.

2.2  Product Contents

O-ring (1)

Anchor

O-ring (1)

Anchor

O-ring (1)

Anchor

Escala

Moderno

Waterfall

Waterfall

Screws (6)

Screws (4)

Waterfall

Screws (4)

O-ring (1)

Anchor

90° Allen

Wrench (1)

Waterfall

Screws (4)

Cambré

Aura14

Aura20

O-ring (1)

Waterfall

Screws (6)

Anchor

Spare Screw (1)

90° Allen

Wrench (1)

Spare Screw (1)

90° Allen

Wrench (1)

Spare Screws (2)

90° Allen

Wrench (1)

Spare Screw (1)

90° Allen

Wrench (1)

Spare

Screws (2)

Summary of Contents for Aura14

Page 1: ...ructions in this manual can be followed exactly Before installing this product read and follow all warning notices and instructions that accompany this product Failure to follow warning notices and instructions may result in property damage personal injury or death Improper installation and or operation may void the warranty ATTENTION INSTALLER This manual contains important information about the ...

Page 2: ...ntenance Instructions 3 Section 2 General Description 4 2 1 Product Overview 4 2 2 Product Contents 4 2 3 Technical Information 5 Section 3 Installing the Grand Effects Freestanding Waterfalls 6 3 1 Preparing the Waterfall for Installation 6 3 2 Water Requirements 7 3 3 Installing the Waterfall 7 Section 4 Dimensions 12 ...

Page 3: ...d follow all warning notices and instructions accompanying this waterfall Failure to follow safety warnings and instructions can result in severe injury death or property damage Visit www fluidra com for additional free copies of these instructions or call Fluidra Technical Support at 800 822 7933 U S or Grand Effects at 949 697 5270 SAVE THESE INSTRUCTIONS ATTENTION INSTALLER This manual contains...

Page 4: ...erfalls are not serviceable and therefore contain no serviceable parts In order to prevent risk of property damage and or injury no service should be attempted to the waterfall in the event of a malfunction 2 2 Product Contents O ring 1 Anchor Waterfall Screws 4 O ring 1 Anchor 90 Allen Wrench 1 Waterfall Screws 4 Cambré Aura14 Aura20 O ring 1 Waterfall Screws 6 Anchor Spare Screw 1 90 Allen Wrenc...

Page 5: ...are Screw 1 Aura20 WFAURA20 Included Anchor Screws 4 O ring 1 Allen Wrench 1 Spare Screw 1 Escala WFESCALA Included Anchor Screws 4 O ring 1 Allen Wrench 1 Spare Screw 1 Cambré WFCAMBRE Included Anchor Screws 6 O ring 1 Allen Wrench 1 Spare Screws 2 Moderno WFMODERNO Included Anchor Screws 6 O ring 1 Allen Wrench 1 Spare Screws 2 2 3 Technical Information Model Part Number Fitting Water Flow gpm A...

Page 6: ...e properly connected to an equipotential bonding grid loop that includes all electrical equipment in the system and on the equipment pad Bonding lugs must be connected with a solid copper wire at least 8 AWG 6 AWG in Canada or larger Failure to do so may void the Fluidra warranty CAUTION To prevent premature failure of the appliance resulting from stray voltages and voltage differentials the stain...

Page 7: ...fall 1 For all waterfalls install the anchor at the height of the top of the deck and connect the bonding cable to the anchor by wrapping the bonding wire around the bonding lug See Figures 2 through 6 NOTE Be careful not to remove the protective film from the anchor 2 8 Cement Cement 2 8 Cement Cement 7 60 6 18 3 94 6 46 7 87 10 95 9 53 7 28 6 46 7 87 AURA14 AURA14 AURA20 AURA20 Figure 2 Aura Wat...

Page 8: ...Page 8 Freestanding Waterfalls Installation and Operation 12 2 10 8 4 7 6 1 2 8 Cement Cement Figure 3 Escala Waterfall Anchor Installation 23 6 7 8 26 8 Figure 4 Cambré Waterfall Footprint Dimensions ...

Page 9: ...nding Waterfalls Installation and Operation Page 9 O ring 7 9 Cement Cement Figure 5 Cambré Waterfall Anchor Installation 21 9 10 1 10 1 3 9 5 5 5 8 Cement Cement Figure 6 Moderno Waterfall Anchor Installation ...

Page 10: ...pool pad Figure 7 Waterfall Plumbing Connections 3 Create a footing of cement around the anchor and piping to provide a solid base for the waterfall The footing should extend at least 3 beyond the perimeter of the anchor and be at a depth of at least twice that of the legs of the anchor See anchor dimensions on pages 7 9 Depth 2 x Height of Anchor Legs 3 Figure 8 Waterfall Cement Base ...

Page 11: ... to the anchor using the provided hardware Ensure the O ring is installed prior to securing the waterfall to the anchor See Figure 8 Anchor Escala Moderno Waterfall Waterfall Screws 6 Screws 4 O ring 1 Anchor O ring 1 Aura14 O ring 1 Anchor Waterfall Screws 4 O ring 1 Waterfall Cambré Screws 6 Anchor Figure 8 Waterfall Hardware Connections ...

Page 12: ...waterfall base 383mm 15 08 400mm 15 8 Aura14 Escala Cambré 735mm 28 94 450mm 17 72 Moderno 383mm 15 08 400mm 15 8 Aura20 700mm 27 56 680mm 26 77 500mm 19 69 Moderno Lip Width 500mm 19 7 Aura14 Lip Width 350mm 13 8 Aura20 Lip Width 500mm 19 7 Cambre Lip Width 600mm 23 6 Escala Lip Width 500mm 19 7 800mm 31 5 620mm 24 41 820mm 32 28 725mm 28 54 Figure 9 Freestanding Waterfalls Dimensions with water ...

Page 13: ...Freestanding Waterfalls Installation and Operation Page 13 NOTES ...

Page 14: ...Page 14 Freestanding Waterfalls Installation and Operation NOTES ...

Page 15: ...Freestanding Waterfalls Installation and Operation Page 15 NOTES ...

Page 16: ...mark of Zodiac International S A S U used under license All other trademarks are the property of their respective owners GE01304142_rel0001 Cover Pools Incorporated 2580 S Decker Lake Blvd Suite 300 West Valley City UT 84119 1 949 697 5270 www GrandEffects com Manual 74338E201 00 ...

Reviews: