background image

2

 

Grand Canyon Gas Logs |3515 E. Atlanta Ave. Phoenix, AZ 85040 

 

JUMBO / JUMBO SLIMLINE BURNER SPECIFICATIONS

 

PART # 

DESCRIPTION 

ITEM WEIGHT 

BTU/HR RATING 

JUMBOSLIMBRNR-24 /-SS 

24" Jumbo Slimline / Stainless Steel Burner 

55.00 

75K-NG / 70K-LP 

JUMBOSLIMBRNR-30 /-SS 

30" Jumbo Slimline / Stainless Steel Burner 

65.00 

110K-NG / 105K-LP 

JUMBOSLIMBRNR-36 /-SS 

36" Jumbo Slimline / Stainless Steel Burner 

75.00 

150K-NG / 145K-LP 

JUMBOSLIMBRNR-42 /-SS 

42" Jumbo Slimline / Stainless Steel Burner 

90.00 

165K-NG / 160K-LP 

JUMBOSLIMBRNR-48 /-SS 

48" Jumbo Slimline / Stainless Steel Burner 

110.00 

195K-NG / 190K-LP 

JUMBOSLIMBRNR-60 /-SS 

60" Jumbo Slimline / Stainless Steel Burner 

140.00 

230K-NG / 225K-LP 

JUMBOSLIMAWO24LOGS 

24" Jumbo Slimline Arizona Weathered Oak Log set 

112.0 

 

JUMBOSLIMAWO30LOGS 

30" Jumbo Slimline Arizona Weathered Oak Log set 

147.0 

 

JUMBOSLIMAWO36LOGS 

36" Jumbo Slimline Arizona Weathered Oak Log set 

188.0 

 

JUMBOSLIMAWO42LOGS 

42" Jumbo Slimline Arizona Weathered Oak Log set 

238.0 

 

JUMBOSLIMAWO48LOGS 

48" Jumbo Slimline Arizona Weathered Oak Log set 

271.0 

 

JUMBOSLIMAWO60LOGS 

60" Jumbo Slimline Arizona Weathered Oak Log set 

309.0 

 

 

 

 

 

JUMBOBRNR-36 /-SS 

36" Jumbo / Stainless Steel Burner 

75.00 

150K-NG / 145K-LP 

JUMBOBRNR-42 /-SS 

42" Jumbo / Stainless Steel Burner 

90.00 

165K-NG / 160K-LP 

JUMBOBRNR-48 /-SS 

48" Jumbo / Stainless Steel Burner 

110.00 

195K-NG / 190K-LP 

JUMBOBRNR-60 /-SS 

60" Jumbo / Stainless Steel Burner 

140.00 

230K-NG / 225K-LP 

JUMBOAWO24LOGS 

24" Jumbo Arizona Weathered Oak Log set 

118.0 

 

JUMBOAWO30LOGS 

30" Jumbo Arizona Weathered Oak Log set 

157.0 

 

JUMBOAWO36LOGS 

36" Jumbo Arizona Weathered Oak Log set 

198.0 

 

JUMBOAWO42LOGS 

42" Jumbo Arizona Weathered Oak Log set 

250.0 

 

JUMBOAWO48LOGS 

48" Jumbo Arizona Weathered Oak Log set 

287.0 

 

JUMBOAWO60LOGS 

60" Jumbo Arizona Weathered Oak Log set 

315.0 

 

 
FIREPLACE SIZE REQUIREMENTS FRONT VIEW 

Burner 

Size 

 

Min. Fireplace Dimensions 

BTU 

Width 

Depth 

Height 

Front 

Rear 

Jumbo 

Slimline 

NAT. 

L.P. 

24

 

36

 

24

 

21

 

24

 

75K 

70K 

30

 

42

 

30

 

21

 

24

 

110K 

105K 

36

 

48

 

36

 

23

 

21

 

24

 

150K 

145K 

42”

 

54”

 

42”

 

23

 

21

 

24

 

165K 

160K 

48

 

60”

 

48

 

23

 

21

 

24

 

195K 

190K 

60”

 

72”

 

60”

 

23

 

21

 

24

 

230K 

225K 

 

Summary of Contents for JUMBOAWO24LOGS

Page 1: ...r s instructions If you cannot reach the gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Grand Canyon Gas Log sets are to be installed only in a solid fuel burning fireplace with working flue and construction of noncombustible material The installation including provisions for combustion and ventilation ai...

Page 2: ... Weathered Oak Log set 238 0 JUMBOSLIMAWO48LOGS 48 Jumbo Slimline Arizona Weathered Oak Log set 271 0 JUMBOSLIMAWO60LOGS 60 Jumbo Slimline Arizona Weathered Oak Log set 309 0 JUMBOBRNR 36 SS 36 Jumbo Stainless Steel Burner 75 00 150K NG 145K LP JUMBOBRNR 42 SS 42 Jumbo Stainless Steel Burner 90 00 165K NG 160K LP JUMBOBRNR 48 SS 48 Jumbo Stainless Steel Burner 110 00 195K NG 190K LP JUMBOBRNR 60 S...

Page 3: ...g based on chimney height and the appliance Btu rating 6 A fireplace screen must be in place when the appliance is operating and unless other provisions for combustion air are provided the screen shall have an opening s for introduction of combustion air With use of glass doors doors must be open while the appliance is burning to assure proper ventilation 7 The minimum inlet supply pressure for th...

Page 4: ...4 Grand Canyon Gas Logs 3515 E Atlanta Ave Phoenix AZ 85040 MINIMUM CHIMNEY HEIGHT AND FLUE OPENING ...

Page 5: ... 1 Remove Merchant Coupling 90 Elbow from the gas inlet side of the burner 2 Drill Out the brass orifice air mixer to the burner and LP orifice size listed below 3 Using piping dope compound replace the orifice air mixer and fitting cap back on the burner Size WC Pressure Minimum BTU Rating Orifice Size 24 11 70K 38 30 11 105K 31 36 11 145K 27 42 11 160K 24 48 11 190K 19 60 11 225K 15 18 21 10 1 2...

Page 6: ... right side of the burner set up burners according to where the gas enters the fireplace 1 Position the burner in the center of the fireplace with or without a valve system 2 Connect whistle free flex to the burner valve the gas inlet BURNER MEDIA INSTALLATION NG Tear or Rip embers in pieces as small as possible Use either a comb or brush to achieve this The smaller the piece the better the ember ...

Page 7: ...on Gas Logs 3515 E Atlanta Ave Phoenix AZ 85040 HIGH CAPACITY SAFETY PILOT HCSPK LP NG HIGH CAPACITY MILLIVOLT HCMVQMKLP NG w GCRK EIS EIS OUTDOOR EIS LP w GCRK EIS OUTDOOR LP w GCRK VALVES PARTS LIST IF PURCHASED ...

Page 8: ...8 Grand Canyon Gas Logs 3515 E Atlanta Ave Phoenix AZ 85040 LOG PLACEMENT GUIDE ...

Page 9: ...or pick up from the dealer at which the burner was originally purchased Stainless Steel Burners installed outside carry a lifetime warranty against manufacturer defects or breakage This warranty is limited to original purchaser only Electrical and Valves Grand Canyon Gas Logs valves pilot assemblies and electrical components carry a 2 year warranty against breakage or defects from date of purchase...

Reviews: