background image

07.

It is important to look at the glycol level (see Topping Up Glycol on page 6) around once per week and 

especially when connecting to additional fermenters. Every time a fermenter, which does not already 

have glycol in its cooling sleeve, is connected to the Glycol Chiller, the glycol level will decrease. Other 

factors such as water evaporation can also affect this level.

NOTE: For optimal performance choose to replace the glycol mixture every 6 months. First you need to 

pump out of the glycol tank all the existing glycol, then refill it with new glycol mixture (see page 5).

If contaminants enter the glycol tank, they can cause blockages. To prevent contaminants from entering 

the glycol tank ALWAYS follow these steps: 
•  Use a clean vessel free from any foreign matter when making up the mixture.
•  Use the included Grainfather Glycol Funnel to transfer mixture into the Glycol Chiller. 
•  Replace the cap immediately after adding the mixture into the tank.

IMPORTANT

Summary of Contents for Glycol chiller

Page 1: ...INSTRUCTIONS GLYCOL CHILLER IMPORTANT BEFORE OPERATING PLEASE SEE INSTRUCTIONS ON PAGE 5...

Page 2: ...Priming pump before first time use p 5 Topping up the glycol tank p 6 Preparing cooling connections p 8 Connecting the chiller to a fermenter p 8 Operating and using the chiller p 9 Connecting more th...

Page 3: ...yer or the greenhouse effect Minimum temperature will vary based on external factors such as ambient room temperature the number of fermenters connected and other environmental conditions INCLUDES A 1...

Page 4: ...rs specifications for more information MAINTENANCE 1 Turn off chiller before cleaning 2 Regularly clean the ventilation louvers using a soft brush 3 DO NOT clean the stainless steel or plastic casing...

Page 5: ...03...

Page 6: ...able throughout the whole fermentation process to ensure the yeast doesn t get stressed and ferments correctly to get the right flavour profile With the ability to individually control the temperature...

Page 7: ...he glycol tank 1 Place the Glycol Chiller close to your Grainfather Conical Fermenter so that all connections can be made without the need to move the unit again 2 Open the cap on the top of the Glyco...

Page 8: ...e as follows 1 2 L 40 US fl oz of mixture consisting of 400 ml 13 5 US fl oz glycol 800 ml 27 US fl oz water if you have just primed your pump and then connected one fermenter 600 ml 20 US fl oz of mi...

Page 9: ...r optimal performance choose to replace the glycol mixture every 6 months First you need to pump out of the glycol tank all the existing glycol then refill it with new glycol mixture see page 5 If con...

Page 10: ...ncrease maximum cooling efficiency Place the chiller and fermenter in their final place measure and cut the hoses accordingly CONNECTING THE CHILLER TO A FERMENTER On the back panel of the Glycol Chil...

Page 11: ...n The glycol needs to be pumped into the cooling sleeve from the bottom to maximise cooling efficiency OPERATING AND USING THE CHILLER 1 Plug the power cord into the back of the Glycol Chiller and the...

Page 12: ...ot already have glycol in its cooling sleeve connected you will need approximately 600 ml 20 US fl oz of additional glycol mixture 2 Check that each fermenter is plugged into the correct connections T...

Page 13: ...is thoroughly first before use We have configured the unit to the optimal settings as to provide the best cooling efficiency from the chiller to a fermenter for ANY required fermentation temperature W...

Page 14: ...the fermenter Connecting lines were clogged or bent Check pipelines Corresponding glycol outlet port not open Identify and press the number button which corresponds to the connections in use Connected...

Page 15: ......

Page 16: ...06 01 www grainfather com Reorder 10233 Version 5...