background image

05.

HOW IT WORKS

This product cools a Grainfather Conical Fermenter to a minimum optimal 

temperature of 4 - 6°C (39 - 43°F)*. The cold glycol can be used to keep the beer in a 

fermenter at a desired temperature.
The glycol chiller includes a pump with 4 connections to make it possible to connect 

and control the temperature of up to four 30 L (8 US Gal) Grainfather Conical 

Fermenters in total.

PRIMING PUMP BEFORE FIRST TIME USE 

IMPORTANT 

Make sure the chiller has been standing upright for 24 hours before turning it ON. Before using the 

Glycol Chiller, you must prime the pump by carefully following the instructions below.

IMPORTANT

Make sure to leave the power to the unit off while completing steps 1 to 4. It is vital that the chiller’s 

compressor does not start until there is water/glycol in the glycol tank.

1.  Place the Glycol Chiller close to your Grainfather Conical Fermenter so that all connections can be 

made without the need to move the unit again.

2.  Open the cap on the top of the Glycol Chiller. Using the included Grainfather Glycol Funnel with 

mesh filter, pour 4 L (1.06 US Gal) of water into the tank. Close the cap and let the chiller rest for a 

minimum of 5 minutes (the longer the better).

3.  Connect a Grainfather Conical Fermenter, via an M12 power cord, to your chiller’s 4th port (at 

the back of the chiller under number 4). Your fermenter will also need to be fitted with a Conical 

Fermenter Digital Controller.

4.  Connect the included silicon hose to the glycol mixture outlet connection (silver in colour with blue 

cap) under number 4. Open the cap and insert the free end of the hose into the opening of the glycol 

tank (shown in the image).

5.  Turn your chiller on by pressing the power button. The power cord will need to be plugged into the 

back of the chiller to provide power.

Summary of Contents for Glycol chiller

Page 1: ...INSTRUCTIONS GLYCOL CHILLER IMPORTANT BEFORE OPERATING PLEASE SEE INSTRUCTIONS ON PAGE 5...

Page 2: ...Priming pump before first time use p 5 Topping up the glycol tank p 6 Preparing cooling connections p 8 Connecting the chiller to a fermenter p 8 Operating and using the chiller p 9 Connecting more th...

Page 3: ...yer or the greenhouse effect Minimum temperature will vary based on external factors such as ambient room temperature the number of fermenters connected and other environmental conditions INCLUDES A 1...

Page 4: ...rs specifications for more information MAINTENANCE 1 Turn off chiller before cleaning 2 Regularly clean the ventilation louvers using a soft brush 3 DO NOT clean the stainless steel or plastic casing...

Page 5: ...03...

Page 6: ...able throughout the whole fermentation process to ensure the yeast doesn t get stressed and ferments correctly to get the right flavour profile With the ability to individually control the temperature...

Page 7: ...he glycol tank 1 Place the Glycol Chiller close to your Grainfather Conical Fermenter so that all connections can be made without the need to move the unit again 2 Open the cap on the top of the Glyco...

Page 8: ...e as follows 1 2 L 40 US fl oz of mixture consisting of 400 ml 13 5 US fl oz glycol 800 ml 27 US fl oz water if you have just primed your pump and then connected one fermenter 600 ml 20 US fl oz of mi...

Page 9: ...r optimal performance choose to replace the glycol mixture every 6 months First you need to pump out of the glycol tank all the existing glycol then refill it with new glycol mixture see page 5 If con...

Page 10: ...ncrease maximum cooling efficiency Place the chiller and fermenter in their final place measure and cut the hoses accordingly CONNECTING THE CHILLER TO A FERMENTER On the back panel of the Glycol Chil...

Page 11: ...n The glycol needs to be pumped into the cooling sleeve from the bottom to maximise cooling efficiency OPERATING AND USING THE CHILLER 1 Plug the power cord into the back of the Glycol Chiller and the...

Page 12: ...ot already have glycol in its cooling sleeve connected you will need approximately 600 ml 20 US fl oz of additional glycol mixture 2 Check that each fermenter is plugged into the correct connections T...

Page 13: ...is thoroughly first before use We have configured the unit to the optimal settings as to provide the best cooling efficiency from the chiller to a fermenter for ANY required fermentation temperature W...

Page 14: ...the fermenter Connecting lines were clogged or bent Check pipelines Corresponding glycol outlet port not open Identify and press the number button which corresponds to the connections in use Connected...

Page 15: ......

Page 16: ...06 01 www grainfather com Reorder 10233 Version 5...