3.
Transport and storage
3.1 Transport
The filters must be secured to prevent shifting and falling during transport. If the filters are secured for
transport using tension belts, make sure that the filters remain undamaged.
Stress caused by impacts must be avoided. The filters must in no event be rolled or dragged across the
ground.
3.2 Storage
If the filters require intermediate storage, this must be done on suitable level ground. During storage,
damage caused by environmental or external factors must be avoided.
4. Technical
data
Description
DN 300 (12”)
connection
DN 400 (16”)
connection
Max. roof area
3.000 m² (32.300 ft
2
)
6.000 m² (65.000 ft
2
)
Max. throughflow
100 l/sec (27 US gal./sec)*
200 l/sec (53 US gal./sec)*
Water yield
over 95%
over 95%
Sprayer through flow
80 l/min (21 US gal./min)
80 l/min (21 US gal./min)
Length
1225 mm (44,3”)
1225 mm (44,3”)
Width
675 mm (26,5”)
675 mm (26,5”)
Height
770 mm (30,7”)
770 mm (30,7”)
Height offset/inlet and outlet
45 mm (1,7”)
45 mm (1,7”)
Inlet connection
DN 300 (12”)
DN 400 (16”)
Sewer connection
DN 300 (12”)
DN 400 (16”)
Filtered water connection
DN 300 (12”)
DN 400 (16”)
Cleaning unit connection
1"
1"
* Dimensioning according to DIN 1986 for horizontal pipelines for a max. partial pipe filling of 0,7 at 1,5%
slope
Side view cross-section
Inlet view
Outlet view
Length
Width
Height