background image

4

. AS

S

EMBLING

 THE

 TELE

SC

OPIC

 DOME

 SHAF

T

Graf UK Ltd

8

4.1 Assembling the telescopic dome shaft 

The telescopic dome shaft enables infinite adaptation 
of the tank to given site surfaces with earth coverage of 
between 455 mm and 655 mm (Mini telescopic dome shaft) 
or 455 mm and 755 mm (Maxi telescopic dome shaft). 

For assembly purposes, the enclosed profile seal (material 
EPDM) is inserted into the tank dome’s sealing groove and 
is coated generously with soft soap (do not use mineral oil-
based lubricants, as these attack the seal). The telescope is 
then greased, inserted and aligned with the surface of the 
site. 

 

4.2 Telescopic dome shaft on which persons may 
walk 

Important:

 To prevent loads from being transferred onto 

the tank, round-grain gravel 

2

 (max. grain size 8/ 16) is 

filled in in layers around the telescope 

1

 and is evenly 

compacted. Damage to the tank dome 

3

 and telescope 

must be avoided during this step. The cover is then 
positioned and is sealed to prevent entry by children. 

Tighten the threaded connection on the cover so tightly 
that it cannot be opened by a child! 

4.3 Telescopic dome shaft over which passenger 
cars may drive 

If the tank is installed under areas used by passenger 
cars, the collar area of the telescope 

1

 (colour anthracite) 

must be supported with concrete 

4

 (load class B25 = 250 

kg/ m

2

). The layer of concrete to be installed must be at 

least 300 mm wide and approx. 200 mm high all around. 
The permitted coverage above the shoulder of the tank 
is min.

 700 mm

 and max. 

1000 mm

. There are different 

possibilities for lengthening the tank dome (315 mm): 
telescopic dome shaft with cast iron lid or Begu (max. 
effective length 440 mm) as well as the dapter (max. 
effective length 300 mm).

Attention:

 Use the cast cover under all circumstances.

4.4 Telescopic dome shaft for HGV loading 

When installing below surfaces driven on by HGVs, the 
telescope is lined 

1

 as described in 7.3. The concrete rings  

6

 (diameter 600 mm) and a cast frame 

5

 with star-shaped 

load distribution are then installed to support the cast 
cover. The cast frame must have a contact area of approx. 1 
m

2

. To extend the shaft, the telescopic dome shaft for HGV 

loading with class D cover, provided by the customer (max. 
useful length 440 mm), and the spacer (max. useful length 
300 mm) can be used. 

Please note: 

Can only be driven over with HGV, if a self-

supporting, steel-reinforced concrete plate is installed.

4

ASSEMBLING THE TELESCOPIC DOME SHAFT

2

3

1

2

3

1

4

6

5

2

3

1

4

Summary of Contents for Garden Comfort Platin 1500 L

Page 1: ...Document No Graf 0004 Rev 1 INSTALLATION MANUAL The Platin tank Garden Comfort system Rainwater Harvesting ...

Page 2: ...al GRAF covers or covers approved in writing by GRAF must be used GRAF offers an extensive range of accessories all of which are designed to match each other and which can be extended to form complete systems The use of accessories that have not been approved by GRAF results in the exclusion of the warranty guarantee 1 2 Identification obligation Regulation The water in these systems is not suitab...

Page 3: ...itres 3000 litres 5000 litres 7500 litres Weight 82 kg 180 kg 250 kg 380 kg L 2100 mm 2450 mm 2890 mm 3600 mm W 1250 mm 2100 mm 2300 mm 2250 mm H 700 mm 735 mm 1000 mm 1250 mm Htot 1015 mm 1050 mm 1315 mm 1565 mm Htot total height without telescopic dome shaft 2 2 Overview tanks Platin 1500 L 3000 L 5000 L 7500 L ...

Page 4: ... determine the physical characteristics of the subsoil 3 2 Trench To ensure that sufficient space is available for working the base area of the trench must exceed the dimensions of the tank by 100 mm on each side the distance from solid constructions must be at least 1000 mm If the depth of the trench is 1250 mm an embankment must be designed according to DIN 4124 The construction site must be hor...

Page 5: ...nsions of the tank by at least 500 mm in all directions and must be located at least 1000 mm away from the tank Attention When positioning the upper half shell it must be ensured under all circumstances that the seal does not slip out of the groove 3 3 4 Groundwater and cohesive water impermeable soils e g clay soil If it is anticipated that the tanks will be immersed deeper into the groundwater t...

Page 6: ...y calculated If you have any questions in this regard please contact your GRAF Team 3 3 7 Installation adjacent to surfaces used by vehicles If the underground tanks are installed adjacent to surfaces which are used by heavy vehicles weighing over 3 5 t the minimum distance away from these surfaces is at least the depth of the trench 3 INSTALLATION ASSEMBLY 3 3 8 Connection of several tanks Two or...

Page 7: ...under any circumstances The surrounding towards the trench must be at least 100 mm wide 3 5 Routing connections All feed and overflow pipes must be routed with a decline of at least 1 in the direction of flow possible subsequent settling must be taken into consideration in this case If the tank overflow is connected to a public sewer this must be protected against reflux by means of a lifting stat...

Page 8: ...er cars may drive If the tank is installed under areas used by passenger cars the collar area of the telescope 1 colour anthracite must be supported with concrete 4 load class B25 250 kg m2 The layer of concrete to be installed must be at least 300 mm wide and approx 200 mm high all around The permitted coverage above the shoulder of the tank is min 700 mm and max 1000 mm There are different possi...

Page 9: ...p is needed Into the highest groove of the extension the profile seal is inserted an greased generously Afterwards push the telescopic dome shaft into the extension and adapt it to the planned area surface 1 Extension max earth cover 955 mm respectively 1055 mm in connection with Mini respectively Maxi telescopic dome shaft Telescopic dome shaft can be inclined by 5 Extension Profile seal Tank dom...

Page 10: ...et at the top of the tank all downpipes brought into one pipe for connection to the filter 100mm diameter pipe for overflow from the tank to mains drainage network or soakaway 6 5 7 3 8 9 1 4 2 1 2 3 4 5 6 7 8 9 5 Ground Fused Spur 13amp 220 240V supply provided by others Power cable for the submersible pump installed within a 50 100mm diameter electrical service duct External Hose Connection Box ...

Page 11: ...oating water extraction unit Water plug socket Version Extern Version Intern 25m roll of HDPE pipe 25mm diameter black green labelled as Rainwater 6 2 Rainwater storage tank Platin set up of internal and external hose connection box Caution The distance between the external hose connection box and the underground tank is limited by the pressure hose length of the pressure hose is 25 m This is the ...

Page 12: ...Graf UK Ltd 12 6 GARDEN SUBMERGE SET INSTALLATION OF TECHNICAL PARTS 6 GARDEN SUBMERGE SET INSTALLATION OF TECHNICAL PARTS 1 2 3 4 5 6 6 3 Installation of internal hose connection box ...

Page 13: ...Graf UK Ltd 13 6 GARDEN SUBMERGE SET INSTALLATION OF TECHNICAL PARTS 6 GARDEN SUBMERGE SET INSTALLATION OF TECHNICAL PARTS 7 9 8 11 10 6 3 Installation of internal hose connection box continued ...

Page 14: ...ot shaft or cistern The difference in height between inlet and outlet is around 100 mm The filter must not be installed in the ground itself The filter is suited to roof surfaces of up to around 200 m2 1 1 1 2 1 1 2 1 1 1 7 2 Filter preparation Before being installed in the tank the enclosed chain suspension 2 must be secured to the filter strainer using the three S shaped hooks supplied 1 and sho...

Page 15: ...ich must protrude at least around 100mm into the filter strainer 1 2 7 4 Installing the filter The stainless steel cross bar supplied 1 is set to the diameter of the telescopic dome shaft min 570 mm max 690 mm and then attached to the shaft s collar The prepared filter 3 is then guided through the tank dome from above slid onto the supply pipe which is protruding at least 100 mm and fitted in the ...

Page 16: ...ing filter is re moved for cleaning and the basket must be thoroughly cleaned with water until all the pores are open It is advised to clean every 4 to 5 weeks more often in autumn due to more leaves and twigs or according to requirements The filter strainer basket must be lightly pressed into place taking care that the seal sits precisely after every cleaning At the occasion of each inspection th...

Page 17: ...cing should be carried out as follows Drain the tank completely Clean surfaces and internal parts with water Remove all dirt from the tank Check that all internal parts are firmly seated The points described in these instructions must be observed under all circumstances All warranty rights are invalidated in the event of non observance Separate installation instructions are enclosed in the transpo...

Page 18: ...Graf UK Ltd 18 15 NOTES 12 NOTES ...

Page 19: ...Graf UK Ltd 19 15 NOTES 15 NOTES ...

Page 20: ...d Scotland 220 Blairtummock Road Queenslie Industrial Estate Glasgow G33 4ED T 0141 465 1540 F 01295 211333 E info grafuk co uk www grafuk co uk R A I N W A T E R H A R V E S T I N G W A S T E W A T E R M A N A G E M E N T S T O R M W A T E R M A N A G E M E N T W A T E R B U T T S C O M P O S T E R S M U L T I P U R P O S E C O N T A I N E R S ...

Reviews: