background image

 

 

 
 
 

 

 

 

 

3 of 13

 

 

 Preliminary Considerations 

 

 

ADDITIONAL WARNINGS  

 

1.1 

Safety Issues 

 

 

All applicable federal, state, and local safety regulations should be observed 

during assembly, installation, maintenance, and/or repair of this equipment.  
When  inspecting  tanks,  we  strongly  recommend  that  a  second  person  be 
present.  

 

When  inspecting  tanks,  particularly  when  standing  on  them,  a  2nd  person 

must be present. 

 

The  installation  of  the  system  or  any  of  its  individual  parts  must  be  con-

ducted by qualified professionals. 

 

The  manufacturer  offers  a  comprehensive  portfolio  of  accessories  that  are 

designed to work with each other and can be developed into complete sys-
tems. Using unapproved components may cause the system to malfunction, 
in which case any existing warranties will not be applicable.  

 

 

Wear safety glasses and gloves when drilling or cutting during this installa-

tion. 

 

DO  NOT  ALLOW  CHILDREN  NEAR  THE  TANK  BEFORE,  DURING,  OR  AFTER 
INSTALLATION WITHOUT DIRECT SUPERVISION BY A COMPETENT PERSON. 

 

1.2 

Compulsory Labelling  

 

All lines, connections, and outlets of water processed with this equipment must be 
labelled with the words “UNTREATED RAINWATER: DO NOT DRINK” in writing or 
graphically  in  order  to  avoid  an  accidental  connection  to  the  drinking  water  net-
work  even  after  years  of  use.  Even  when  there  are  correct  labels,  mistakes  are 
possible  if  children  or  other  persons  unfamiliar  with  the  system  are  allowed  ac-
cess.  

 

Additionally, all points where water processed by this system is accessible outside 
the system must be equipped with child-proof valves. 

 

1.3 

State Regulations 

The State of Colorado has strict requirements governing the diversion and use of 
rainwater.      Please  check  local  and  state  requirements  to  see  if  special  approval 
must  be  obtained  before  the  installation  of this  or  any  other  rainwater  harvesting 
equipment. 

 

 

1.  Preliminary Considerations 

Summary of Contents for 81011001

Page 1: ... items you have purchased Keep this instruction manual and make it available for all end users FAILURE TO COMPLY WITH THESE INSTRUCTIONS CAN RESULT IN SERIOUS PERSONAL UNJURY OR DEATH AND OR SEVERE PROPERTY DAMAGE Watts is not responsible for any damages or injuries that result from improper installation and or use 700 gallons 2700 litres Order No 81011001 1000 gallons 3750 litres Order No 8101100...

Page 2: ...tem should only be used to water outdoor plantings wash vehicles or use in other outdoor cleaning tasks Water may be stag nant or contaminated and can cause serious illness and or death if in gested When working on any electrical system and or system components the en tire system must be disabled by disconnecting it from any and all power sources to prevent an accidental restart Except in the even...

Page 3: ...or cutting during this installa tion DO NOT ALLOW CHILDREN NEAR THE TANK BEFORE DURING OR AFTER INSTALLATION WITHOUT DIRECT SUPERVISION BY A COMPETENT PERSON 1 2 Compulsory Labelling All lines connections and outlets of water processed with this equipment must be labelled with the words UNTREATED RAINWATER DO NOT DRINK in writing or graphically in order to avoid an accidental connection to the dri...

Page 4: ... No 81011001 81011002 81011003 81010059 Weight 321 5lbs 120 kg 401 8lbs 150 kg 495 6lbs 185 kg 589 4lbs 220 kg L 81 9 2080 mm 89 8 2280 mm 89 8 2280 mm 94 2390 mm W 61 6 1565 mm 69 1755 mm 78 1 1985 mm 86 2190 mm H 55 1 1400 mm 62 6 1590 mm 71 7 1820 mm 82 7 2100 mm Htot 79 1 2010 mm 86 6 2200 mm 95 7 2430 mm 106 7 2710 mm 2 Technical data 47 2 ...

Page 5: ...ructure Cover Telescopic dome shaft can be inclined by 5 Profile seal Tank dome can be rotated by 360 Tank tank dome seal Upper half shell open Centering pins Circumferential seal Quick connector Lower half shell closed ...

Page 6: ...l the quick connectors attach them in an alternating manner to the left and to the right counter clockwise and clockwise For this every second connector should be adjusted by hand initially and then driven securely into place using a hammer and a block of wood If attaching the clips is problematic try lubricating the inner edges of the connectors and or using 3 4 C clamps positioned evenly around ...

Page 7: ...nd 37 4 950 mm and the Maxi telescopic dome shaft extends 29 5 750 mm and 41 3 1050 mm For assembly purposes the enclosed profile seal EPDM is inserted into the tank dome s upper sealing groove and is coated generously with soft soap do not use mineral oil based lubricants as these attack the seal The telescopic dome is then greased inserted and aligned with the surface of the site 5 3 Assembling ...

Page 8: ...tallation The structural suitability of the ground for this purpose minimum depth of water table maximum groundwater levels and porosity drainage capability of the subsoil types of load which will occur above the tank location In order to determine the soil composition and suitability for the project local building codes and governing agencies should be consulted ...

Page 9: ...rian traffic only Maximum coverage heights with intermediate section and telescopic dome shaft in green areas pedestrian only insertion above water table Coverage heights with cast iron telescopic dome shaft class B in areas used by passenger cars insertion above water table The Carat S series tanks must not be installed below areas used by vehicles that are heavier than passenger cars Coverage he...

Page 10: ... capabilities a reinforced concrete slab approx 4 thick should be poured to ensure stability 6 2 1 Slope embankment etc On installation of the tank in the immediate vicinity 16 ft 5 m of a hillside mound or slope a statically calculated supporting wall has to be constructed in order to accept the soil pressure The wall must exceed the dimensions of the tank by at least 20 500 mm in all directions ...

Page 11: ...al compaction machines must not be used under any circumstances 6 4 Telescopic dome shaft pedestrian Pedestrian load bearing dome shaft can handle weights of up to 330 lbs 150 kg for short periods and 110 lbs 50 kg for extended periods of time Important To prevent loads from being transferred onto the tank pea gravel max grain size 8 16 is filled in in layers around the telescope and is evenly com...

Page 12: ...I S _ WQ P _ C A R A T _ 0 9 2 2 2 Wa t t s 2 0 0 9 ...