8-10
Chapter 8: Canyon 456
The amperage requirements of the Seakeeper can vary depending on the status of the spool up
process, as well as sea conditions� The highest amperage requirement the Seakeeper will have is
during start-up as shown in the table below� The Seakeeper spool up process can be started at the
dock while still on shore power to reduce impact on the use of other AC devices� Please refer to
“Seakeeper” on page 8-11
for recommended spool up times�
• Air Conditioner-Cabin
11�7A
(5�9A) 50Hz
Running Amps
• Air Conditioner-Helm
11�7A
(5�9A) 50Hz
Running Amps
• Air/Cooler Pump
2�1A
(1�1A) 50Hz
Running Amps
• Battery Charger Port
8�0A
(4�0A) 50Hz
Maximum Amps
• Battery Charger Starboard
8�0A
(4�0A) 50Hz
Maximum Amps
• Battery Charger Thruster
2�0A
(1�0A) 50Hz
Maximum Amps
• Cockpit Cooler
6�6A
(3�3A) 50Hz
Running Amps
• Grill
10�8A
(5�4A) 50Hz
Maximum Amps
• Microwave
12�5A
(6�3A) 50Hz
Maximum Amps
• Refrigerator Galley
2�5A
(1�3A) 50Hz
Maximum Amps
• Refrigerator Leanbar
2�5A
(1�3A) 50Hz
Maximum Amps
• Seakeeper
19�2
(9�6A) 50Hz
Maximum Amps
• Seakeeper Pump
2�0A
(1�0A) 50Hz
Maximum Amps
• Stovetop
(per burner)
10�0A
(5�0A) 50Hz
Maximum Amps
• Water Heater
12�5A
(6�3A) 50Hz
Maximum Amps
Generator Cover
A generator cover is included with the generator� This provides protection against the elements
to prolong the life of the unit� It should be kept in place at all times except when servicing the
generator�
Summary of Contents for Canyon 456
Page 2: ......
Page 8: ...Table of Contents ...
Page 12: ...1 4 Chapter 1 Consumer Information ...
Page 28: ...3 8 Chapter 3 General Information ...
Page 38: ...5 6 Chapter 5 Instrumentation ...
Page 40: ...5 8 Chapter 5 Instrumentation ...
Page 47: ...6 7 Chapter 6 Maintenance and Service ...
Page 48: ...6 8 Chapter 6 Maintenance and Service ...
Page 50: ...6 10 Chapter 6 Maintenance and Service ...
Page 79: ...8 19 Chapter 8 Canyon 456 ...
Page 86: ...8 26 Chapter 8 Canyon 456 ...
Page 88: ...8 28 Chapter 8 Canyon 456 ...