Repair
36
334513N
Check Valve Repair
The following procedures apply to the check valves on
Wolverine Advanced and Wolverine Hazardous Loca
-
tion pumps. F
IG
. 27 shows the placement of the check
valves on a Wolverine Advanced pump.
Inlet Check Valve
on page 23.
2. Remove the inlet check valve assembly (215).
3. Remove the retaining nut (215c) and piston (215b).
4. Remove the piston o-ring (215a) from the piston (215b).
5. Inspect parts for wear, and replace as needed.
6. Install the piston o-ring (215a).
7. Reassemble the piston (215b) and retaining nut (215c).
Torque the retaining nut to 30-35 in-lbs.
8. Reconnect the inlet check valve assembly (215). Apply
sealant to the exterior threads of the valve assembly.
9. Reconnect and tighten fluid lines.
10.
, page 24.
Outlet Check Valve
on page 23.
2. Remove the outlet check valve assembly (216).
3. Remove the retaining nut (216c), spring (216d), and pis
-
ton (216b).
4. Remove the piston o-ring (216a) from the piston (216b).
5. Inspect parts for wear, and replace as needed.
6. Install the piston o-ring (216a).
7. Reassemble the piston (216b), spring (216d), and retain
-
ing nut (216c). Torque the retaining nut to 30-35 in-lbs.
8. Reconnect the outlet check valve assembly (216). Apply
sealant to the exterior threads of the valve assembly.
9. Reconnect and tighten fluid lines.
10.
, page 24.
F
IG
. 27 Check Valve Repair
216c
216b
216a
216
215c
215b
215a
215
210
216d
212
211