Model and Component Identification
334513N
21
For Hazardous Location (C1 D1)
(models CI-xxH)
The pump assembly has motor leads housed inside the
motor junction box. See F
IG
. 4 on page 14.
1. Remove the motor junction box cover.
2. Connect wires and related conduit (user-supplied)
rated per local electrical code. See F
10 for wiring diagrams, and
, on 60, for current ratings.
3. Connect a user-supplied ground wire to the ground
stud inside the motor junction-box.
4. Replace motor junction box cover.
For ATEX AC (models CI-2AX and CI-5AX)
The pump assembly has motor leads housed inside the
back cover plate of the motor. See F
1. Remove the rear cover plate of motor.
2. Connect wires and related conduit (user supplied)
rated per local electrical code. See F
IG
. 10 and F
IG
.
11 for wiring diagrams, and
Technical Specifica
-
tions
, on page 58, for current ratings.
3. Connect a user-supplied ground wire to the ground
stud inside the motor cover plate.
4. Replace the motor junction box.
F
IG
. 9 Electrical Connections for Single Phase Pump
F
IG
. 10 Electrical Connections for 3 Phase Pump
P1
RED
P2
ORANGE
BLACK
WHITE
YELLOW
LINE 1
INSULATE
LINE 2
MOTOR
P1
P2
RED
ORANGE
WHITE
BLACK
YELLOW
LINE 1
INSULATE
INSULATE
LINE 2
MOTOR
115 V / Single Phase (Low Voltage)
230 V / Single Phase (High Voltage)
LINE 3
LINE 2
LINE 1
T1
T7
T2
T8
T3
T9
T4
P4
T5
P5
T6
P6
MOTOR
LINE 3
LINE 2
LINE 1
T1
T2
T3
P4
P5
P6
T4
T7
T6
T9
T5
T8
MOTOR
230 V / 3 Phase (Low Voltage)
460 V / 3 Phase (High Voltage)
F
IG
. 11 Electrical connections for Single Phase
Pump
F
IG
. 12 Electrical connections for 3 Phase AC Pumps
BLACK
BLACK
LINE 1*
LINE 2*
MOTOR
*Order does not matter
BROWN
BLACK
BLUE
LINE 1
LINE 2
LINE 3
MOTOR